ENVEA - Model MS1 -Probe Dilution-Based Stack Gas Sampling System
FromENVEA
Gas Sampling system for use in combination with low concentration analyzers (Ambient Air type).
Most popular related searches
gas sampling system
gas sampling
stack gas sampling system
sample gas
stationary monitoring system
stack gas sampling
dilution stack sampling
hazardous area
stationary monitoring
compressed air
- Refineries and petrochemical industries, use in hazardous areas
- Power plants
- Very low sampling rate, avoiding clogging issues, and immediate dilution at the sampling point
- Transfert of the sample gas (up to 150m) by an unheated line, with no risk of condensation
- Minimum maintenance of the probe (several months of unattended operation)
- Calibration control of the monitoring system by direct injection of span gas directly at the top of the probe
- No electricity or moving part in the probe and sample line
- Low installation cost
- Remote maintenance possibility via serial output
- Multiprobes: from 1 to 4 probes connected to a single set of analyzers
- Maximum sample gas temperature:
- standard probe: + 400°C - quartz probe: + 600°C
- Dilution rate: 12/1 to 350/1 according to the type of critical orifice selected (sampling from 20ml/mn to 500 ml/mn)
- Accuracy of dilution rate: ± 2 %
- Compressed air: 400 Nl/h, 5 to 7 bars
- Probe dimensions: 27 mm external diameter, 60 cm standard length (body made of special alloy)
- Umbilical cord length: 5 to 150 m
- MS1 housing : 19`` rack / 4U