ENVEA
  1. Companies
  2. ENVEA
  3. Products
  4. ENVEA - Model NDIR-GFC - MIR 9000P - ...

ENVEAModel NDIR-GFC - MIR 9000P -Portable Multi-Gas Analyzer

FromENVEA
SHARE

The MIR 9000P belongs to the new generation of ENVEA gas monitors, showcasing eco-design, IoT and on board intelligence. It measures simultaneously 8 gases – NOx, SO2, CO, CO2, CH4, N2O, O2 and residual H2O – and uses the non-dispersive infrared method (NDIR-GFC) with gas filter correlation. O2 is measured by a built-in SRM paramagnetic sensor. The analyzer has been designed to meet the specific needs of on-site regulatory measurement providing superior mobility, robustness, accuracy and compliance. All this makes up for a unique gas emission monitor offering high productivity and low operational cost.

Most popular related searches
  • INCREASED MOBILITY & PRODUCTIVITY

    • Lightweight (15 kg/33 lbs), compact and extra resistant transport case
    • Standby mode guarantees the instrument is operational at any time

    ROBUST DESIGN

    • Extended operating temperature ranges
    • High protection (IP 44) against water splashing from any direction

    STAY CONNECTED & GET ON WITH OTHER TASKS

    • Remote access to full operation thanks to ENVEA Connect™ App and proprietary WiFi
    • Smartphone alerts and notifications

    ONE CLICK OPERATIONS

    • Integrated user guidance and shortcuts to key functions: calibrations, span check, zero, etc.
    • Secured user management

    QUICK INSTALLATION

    • Warm-up time: 30 min maximum
    • Robust gas connectors
    • Self-adaptive measuring scales
    • Compatible with most sampling systems on the market

    PREPARE REPORT ELEMENTS WHILE ON SITE

    • Direct access to real-time and stored data ; time frame selection to generate graphs
    • All data can be saved on USB memory stick

    MAXIMIZED UPTIME OF THE ANALYZER

    • Turn-up lid designed for quick access to operational modules and easy maintenance
    • Modular design and Plug & Play parts (O2 probe, NOx converter, protection filter, etc.)
  • Regulatory and periodic stack emission monitoring for industrial combustion sites, boilers, etc.

Measuring Ranges

  • NOx as NO (after NOx converter): 0-70/2000/3300 mg/Nm3 0-50/1500/2500 ppm
  • NOx as NO2 (after NOx converter): 0-110/3000/5000 mg/Nm3
  • SO2: 0-141/1410/8500 mg/ Nm3 , 0-50/500/3000 ppm
  • CO: 0-60/3000/8000 mg/Nm3, 0-50/2400/6500 ppm
  • CO2: 0-20/30% vol.
  • N2O: 0-1000 mg/Nm3, 0-500 ppm
  • CH4: 0-70/700 mg/Nm3, 0-100/1000 ppm (higher range upon request)
  • O2: 0-10/25% vol. measured by a built-in paramagnetic sensor Residual H2O: 0-2% vol.

Technical Specifications

  • QAL1 to EN 15267-4 certified: Pending
  • US EPA compliance: YES
  • Sampling technology: Cold/Dry Extraction (gas cooler)
  • Sample transfert: non heated polytube / heated sampling line
  • back flush function: N/A
  • span injection: YES
  • Built-In O2 option: YES
  • Serial link communication: 3 x USB ports type A: 2.0 (compatible 3.0)
  • 1 x RJ45 (MODBUS TCP, MODBUS RTU (dongle) UDP Protocol)
  • Other Communication: WiFi (via USB)
  • Analogue OUTPUTS: Option: 8 analog outputs (0-1 V, 0-10 V, 0-20 mA, ou 4-20 mA)
  • Analogue INPUTS: Dynamic 250 mV or 10V (only one input can be used at once)
  • Dimensions (mm): 641 x 209 x 393mm (WxDxH)
  • QAL1 certification by the TÜV according to EN 15267-1, EN 15267-2 and EN 15267-4. Download the TÜV certificate: 0000074636
  • Compliant with EN 15267-4
    Air quality – Certification of automated measuring systems – Part 4: Performance criteria and test procedures for automated measuring systems for periodic measurements of emissions from stationary sources
  • Compliant with US EPA