ENVEA
  1. Companies
  2. ENVEA
  3. Products
  4. ENVEA - Model Paddy - Particle Size ...

ENVEAModel Paddy -Particle Size Monitoring

FromENVEA
SHARE

Paddy has been developed to supply a trending information of pulverization. It measures changes in particle size for instance to detect screen breaks. Paddy is insensitive against contaminations and works without a bypass.

Most popular related searches
  • Supply a trending information of pulverization
  • Measures changes in particle size for instance to detect screen breaks
  • Paddy is insensitive against contaminations and works without bypass
  • Uses state-of-the-art microwave technology in combination with intelligent evaluation software
  • Can be installed in free-fall pipes downstream from screening or grinding systems
  • Fast detection of coarse particles, for as little as 10 % of the mass flow
  • Cement
  • Food
  • Wood
  • Cement
  • Food
  • Wood
  • Material to measure: Dust, powders or granulates, not agglomerated
  • Process pressure: 1 bar, optional 10 bar
  • Process temperature: Max. 80°C
  • Mounting: Via process connection, after baffle plate or Venturi
  • Type of Conveying: Pneumatic leanphase, vertical freefall
  • ATEX rating: Category 1/2
  • Output: 4…20mA Trend, Modbus, Profibus
  • Fast detection of coarse particles, for as little as 10 % of the mass flow
  • Uses state-of-the-art microwave technology in combination with intelligent evaluation software
  • Can be installed in free-fall pipes downstream from screening or grinding systems
  • Possibility of trend showing for grain size
  • Special freefall section include baffle plates needed
  • Consists of two sensors (measurement and reference)

Sensor Technical Data

  • Measurement principle: Microwave
  • Measurement range: Particle sizes up to 10 mm –
  • larger sizes on request
  • Housing material: Stainless steel 1.4571
  • Protection type: IP 65, dust explosion zone 20 or
  • gas explosion zone 1 (optional)
  • Ambient operating temperature: Sensor tip: -20 … +80 °C
  • Optional: -20 … +200 °C
  • Sensor element: 0 … +60 °C
  • Max. operating pressure: 1 bar
  • Operating frequency: K band 24.125 GHz, ±100 MHz
  • Transmission power: Max. 5 mW
  • Weight: 1.3 kg
  • Dimensions: Ø 60, Ø 20, L 271 mm