ENVEA

- Model PCME QAL 182 WS - Particulate CEM for Wet Gas Streams

From

0

QAL1 approved ProScatterTM particulate CEM for the extractive sampling and measurement of particulate in saturated wet gas streams. Continuous Particulate Monitoring for saturated wet stack applications typically found after wet scrubbers, wet electrostatic precipitators and wet flue gas desulphurisation plant.

  • Extractive sampling system configurable for fixed velocity or isokinetic variable flow rate sampling
  • Continuous Particulate Monitoring for saturated wet stack applications typically found after wet FGDs or filtration systems that produce a wet/condensing flue gas (wet ESPs/scrubbers)
  • Meets QAL1 and other International standards
  • Extractive sampling system configurable for fixed velocity or isokinetic variable flow rate sampling
  • Heated sample lines to maintain sample temperature and prevent the formation of condensation
  • Forward Scatter measurement technique with automatic zero and span (upscale) checks
  • Easy to use intuitive multi-lingual menu with large display for improved user interface complete with on-board diagnostics and multiple analogue and digital communication outputs
  • Small sample chamber and use of advanced polymers – prevents particulate adhesion, condensation and crystal formation. Reduced maintenance for the end user

Stacks with saturated wet flue gas, typically after wet flue gas desulphurisation plant, wet collectors, etc

Typical Applications:

  • Power Generation Plant eg Coal/Biomass
  • Incineration
  • Metals eg Steel/Aluminium
  • Minerals eg Cement/Gypsum
  • Chemicals eg Detergent / Carbon Black
  • Fertiliser
  • Pulp and Paper

  • Measured parameters: Dust
  • Technology: Extractive ProScatterTM Forward Scatter
  • Measurement/Monitoring capability: 0-500 mg/m³*
  • Stack/Duct diameter suitability: up to 15m
  • Flue gas temperature: up to 200°C
  • Baghouse: /
  • Cartridge Filter: /
  • Ceramic Filter: /
  • Coalescent Filter: /
  • Cyclone: /
  • Electrostatic Precipitator (ESP): /
  • Wet Electrostatic Precipitator (WESP): YES
  • Wet Scrubber: YES
  • Sensor variants: PVDF corrosion resistant
  • Stainless Steel
  • Hastelloy®
  • QA checks: YES

*Application dependant

  • Measurement capability: 0 – 500 mg/m3 (for higher concentrations, please consult ENVEA)
  • Detection Limit: < 0.1 mg/m3
  • Probe Variants:
    • Probe lengths 600mm, 1200mm (other lengths available on request)
    • PVDF (standard) corrosion resistant
    • Stainless Steel: non-corrosive stacks
    • Hastelloy® corrosion resistant
  • Stack Temperature Ranges: up to 200°C
  • Functionality and QA Checks: Automatic self-checks (zero and span), QA data logging
  • Outputs: RS485 (Modbus) RS232 (Modbus) Ethernet

  • TÜV (UBA) certified to EN15267-3
  • QAL1 as defined by EN14181
  • QAL3 compliance to EN14181

Customer reviews

No reviews were found for ENVEA - Model PCME QAL 182 WS - Particulate CEM for Wet Gas Streams. Be the first to review!