Most popular related searches
particulate continuous emissions monitor
wet electrostatic precipitator
flue gas
flue gas velocity
flue gas desulfurization
wet electrostatic precipitation
electrostatic precipitator
electrostatic precipitation
wet scrubber
CEMS
- Robust design with no moving parts in the optical system
- Available for use in high-temperature or corrosive stack conditions and Ex hazardous zones
- Easy to fit multi-patterned flange
- Adjustable monitoring depth to ensure sampling in the most representative part of the flow path
- For use as PM-CPMS or PM-CEMS that need to comply with US EPA PS-11
- ProScatter® technology offers enhanced measurement due to reduced cross-sensitivity of particle type and size
- Features automatic zero and upscale checks that fully challenge the system’s ability to measure forward-scattered light and satisfy daily drift checks
- Easily audited with manual filters
- Stacks below dew point / with water droplets
- After wet scrubber arrestment plant
- After Flue Gas Desulphurisation (FGD) plant
- Flue gas velocity range 1-20m/s
- Corrosive flue gases (corrosion protection option)
- Variable particulate size
Typical Applications:
- Incineration
- Metals (eg Steel/Aluminium)
- Minerals (eg Cement/Gypsum)
- Chemicals (eg Detergent / Carbon Black)
- Power Generation Plant (eg Coal/Biomass)
- Measured parameters: Dust
- Technology: Extractive ProScatterTM Forward Scatter
- Measurement/Monitoring capability: 0-500 mg/m³*
- Stack/Duct diameter suitability: up to 15m
- Flue gas temperature: up to 200°C
- Baghouse: /
- Cartridge Filter: /
- Ceramic Filter: /
- Coalescent Filter: /
- Cyclone: /
- Electrostatic Precipitator (ESP): /
- Wet Electrostatic Precipitator (WESP): YES
- Wet Scrubber: YES
- Sensor variants: PVDF corrosion resistant
- Stainless Steel
- Hastelloy®
- QA checks: YES
*Application dependant
- Measurement capability: 0 – 1000 mg/m3
- Certification Range: 0 – 15 mg/m3
- 0 – 100 mg/m3
- Resolution: 0.01 mg/m3
- Sensor Variants: Stainless Steel (standard) Corrosion resistant Hastelloy (option)
- Stack Temperature Ranges: 0-250°C. Up to 500°C option
- Functionality and QA Checks: Automatic zero and upscale checks QA data logging
- Data Output: RS485 (Modbus) output to Controller
- Air Purge: requires continuous air purge
- Enclosure Protection Rating: IP66
- PS-11 compliant
- Ex Zone 2