ENVEA

- Model PCME STACK 181 WS - Particulate CEM for Wet Gas Stream

From

0

US EPA PS11 capable ProScatter™ particulate CEM for the extractive sampling and measurement of particulate in saturated wet gas streams.

  • Robust design with no moving parts in the optical system
  • Available for use in high-temperature or corrosive stack conditions and Ex hazardous zones
  • Easy to fit multi-patterned flange
  • Adjustable monitoring depth to ensure sampling in the most representative part of the flow path
  • For use as PM-CPMS or PM-CEMS that need to comply with US EPA PS-11
  • ProScatter® technology offers enhanced measurement due to reduced cross-sensitivity of particle type and size
  • Features automatic zero and upscale checks that fully challenge the system’s ability to measure forward-scattered light and satisfy daily drift checks
  • Easily audited with manual filters

  • Stacks below dew point / with water droplets
  • After wet scrubber arrestment plant
  • After Flue Gas Desulphurisation (FGD) plant
  • Flue gas velocity range 1-20m/s
  • Corrosive flue gases (corrosion protection option)
  • Variable particulate size

Typical Applications:

  • Incineration
  • Metals (eg Steel/Aluminium)
  • Minerals (eg Cement/Gypsum)
  • Chemicals (eg Detergent / Carbon Black)
  • Power Generation Plant (eg Coal/Biomass)

  • Measured parameters: Dust
  • Technology: Extractive ProScatterTM Forward Scatter
  • Measurement/Monitoring capability: 0-500 mg/m³*
  • Stack/Duct diameter suitability: up to 15m
  • Flue gas temperature: up to 200°C
  • Baghouse: /
  • Cartridge Filter: /
  • Ceramic Filter: /
  • Coalescent Filter: /
  • Cyclone: /
  • Electrostatic Precipitator (ESP): /
  • Wet Electrostatic Precipitator (WESP): YES
  • Wet Scrubber: YES
  • Sensor variants: PVDF corrosion resistant
  • Stainless Steel
  • Hastelloy®
  • QA checks: YES

*Application dependant

  • Measurement capability: 0 – 1000 mg/m3
  • Certification Range: 0 – 15 mg/m3
  • 0 – 100 mg/m3
  • Resolution: 0.01 mg/m3
  • Sensor Variants: Stainless Steel (standard) Corrosion resistant Hastelloy (option)
  • Stack Temperature Ranges: 0-250°C. Up to 500°C option
  • Functionality and QA Checks: Automatic zero and upscale checks QA data logging
  • Data Output: RS485 (Modbus) output to Controller
  • Air Purge: requires continuous air purge
  • Enclosure Protection Rating: IP66

  • PS-11 compliant
  • Ex Zone 2

Customer reviews

No reviews were found for ENVEA - Model PCME STACK 181 WS - Particulate CEM for Wet Gas Stream. Be the first to review!