ENVEA
  1. Companies
  2. ENVEA
  3. Products
  4. ENVEA - Model PCME VIEW 800 - ...

ENVEAModel PCME VIEW 800 -ElectroDynamic Multi-Sensor Dust Monitor

FromENVEA
SHARE

Multi-Sensor Dust Monitor certified to category 1 under ATEX / IECEx designed for indicative emissions trending and measurement in challenging hazardous zone. Advanced Probe Electrification technology, perfectly adapted for particulate monitoring after bag filters, cartridge filters, cyclones and process driers, where regulatory approvals are not necessary.

Most popular related searches
  • Reliable measurement of leaking and broken bags in dust collectors
  • Senor configured remotly via controller
  • Automatic sensor drift checks (zero and span)
  • Automatic probe check (Insulator Short-Circuit Check) for improved data integrity
  • Reduces filter maintenance intervals, process down-time and filter costs
  • Stacks after bag filters, cartridge filters, cyclones
  • Variable velocities within range 4-30 m/s (typical bagfilter velocity ranges), constant velocity required outside this range
    • Explosive atmosphere zones 0, 1, 2, 20, 21 and 22

Typical Applications:

  • Minerals (eg Coal Gasification)
  • Petrochemicals (eg Plastics manufacture)
  • Power (eg Biomas)
  • Measured parameters: Dust
  • Technology: ElectroDynamic® Advanced Probe Electrification
  • Measurement/Monitoring capability: 0-500 mg/m³*
  • Stack/Duct diameter suitability: up to 6m
  • Flue gas temperature: up to 250°C
  • Baghouse: YES
  • Cartridge Filter: YES
  • Ceramic Filter: /
  • Coalescent Filter: /
  • Cyclone: YES
  • Electrostatic Precipitator (ESP): /
  • Wet Electrostatic Precipitator (WESP): /
  • Wet Scrubber: /
  • Sensor variants: Stainless Steel
  • QA checks: N/A

*Application dependant

  • Monitoring capability: 0-500 mg/m3
  • Sensor Variants: 316 Stainless Steel (standard)
  • Stack Temperature Ranges: 0-250°C
  • Pressure Rating: < 2Bar
  • On-board data logging: User configurable Long term, Short term or Pulse logging
  • Outputs: RS232, RS485 (Modbus), Ethernet Digital Alarm and 4/20mA (number of outputs dependant on controller type)
  • Ex Zone 0, 1, 2
  • US EPA MACT Compliant BLD