ENVEA - Model ProGap 2.0 - Point Level Monitoring Microwave Barrier
From Process Optimization - Level Monitoring
Microwave barrier for contactless detection of dry bulk solids in containers, pipes or chutes. Reliable fill level and limit detection.
Features & Benefits
- Simple and uncomplicated retrofitting
- Reliable fill level and limit level detection
- Signalling through relay switching
- Detection through all non-conductive walls
- With process adapter up to 220 °C and 20 bar pressure possible
- With ceramic mounting up to 1,000 °C possible
- Absolutely insensitive to material cakings
- Can be used up to a profile of 25 m (larger profiles on request)
- Compact device – no separate electronics
- Can also be supplied in short housing with separate electronics
Main Applications
- Limestone
- Tiling
- Waste incineration
- Cement
- Building materials
Technical Specifications
- Material to measure: Dust, powders or granulates
- Working principle: Microwave
- Silo diamter/ detection range: 25m
- Process pressure: Max. 20 bar
- Process temperature: Up to 1000°C
- Mounting: 1 1/2 ” threat connection
- Place to measure: Silos, containers, chutes, pipelines, transition points
- Output: Relay
Technical Data
Sensor Technical Data
- Material: Housing: Stainless steel 1.4571
- Sensor-Isolation: POM
- Protective system: IP 65
- Using in Ex-zones: Outside pipe: Cat. 3 GD
- Inside pipe: Cat. 1/3 G and Cat. 1/3 D
- (only with process adapter)
- Dimension
- ProGap 2.0-BS: Housing: L 103 mm / Ø 52 mm
- Thread: L 30 mm / Ø G1½
- Dimension
- ProGap 2.0-BS Ex: Dimension
- ProGap 2.0-BS Ex
- Process temperature: -20 … + 80 °C
- -20 …+220 °C (with process adapter)
- max. 1000 °C (with ceramic flange)
- Ambient temperature: -20…+60 °C
- Working pressure: max. 1 bar
- max. 20 bar (with process adapter)
- Detection range: Leveln: 0.1 … 25 m (> 25 m on request)
- Detection range: Flow: 0.1 … 12,5 m (> 12,5 m on request)
- Power supply: 24 V DC powered by DIN Rail electronic
- Power consumption: approx. 1.8 VA
- Current consumption: max. 100 mA
- Measuring frequency: K-Band 24.125 GHz (± 100 MHz)
- Transmitting powe: max. 5 mW
- Cable gland: M16 (Ø 5-10 mm)
- Weight ProGap 2.0-BS: approx. 560 g
- Weight ProGap 2.0-BS Ex:
- Transmitter: 1.1 kg
- Receiver: 1.1 kg
DIN Rail electronic Technical Data
- Power supply: 24 V DC ± 10 %
- Power consumption: 3.5 W
- Current consumption: 120 mA at 24 V
- Relay contact: Max. rated load: 250 V AC
- Max. peak current: 6 A
- Max. rated load 230 V AC: 250 VA
- Max. breaking capacity DC1:
- 3/110/220 V: 3/0.35/0.2 A
- Min. switching load:
- 500 mW (10 V/5 mA)
- Fall-delay time: 0.25 …5 s (continuously adjustable)
- Weight: approx. 172 g
- Protective system: IP 40
Mounting & Installation
The transmitter and receiver are installed by screwing into a G 1 ½” threaded connection. The device can be installed at any installation height. It is important that the transmitter and receiver have the same installation height. The adjustment takes place with the help of a counter-threaded connection.
A display of the signal intensity facilitates the adjustment. The connection to the power supply takes place on the transmitter and the receiver. The switch output is made available on the receiver. No additional analysis unit is necessary.