ENVEA
  1. Companies
  2. ENVEA
  3. Products
  4. ENVEA - Model VOC72e - Volatile Organic ...

ENVEAModel VOC72e -Volatile Organic Compounds Analyzer BTEX

FromENVEA
SHARE

Gas chromatography (GC) coupled with a PID detector. VOC monitor QAL1 certified to EN 14662-3 standard for benzene measurement. Compact and fully automated analyser providing equal performance to the laboratory chromatographs; particularly well-suited for fixed or mobile ambient air quality monitoring stations. Standard measured compounds: Benzene, Toluene, Ethylbenzene, m+p-Xylene, o-Xylene, 1-3 Butadiene (other compounds on request).

Most popular related searches
  • Standard measured compounds: Benzene, Toluene, Ethylbenzene, m+p-Xylene, o-Xylene, 1-3 Butadiene…
  • Performs all the functions, such as: sampling, analysis and data management, in a simple and completely autonomous mode
  • Self-contained, completely automated and ready to use in less than 30 minutes
  • GC column equipped with an innovative liquid-cooler; retention times are stable even with a fluctuating temperature
  • Long-life capillary column
  • High sensitivity, stable and linear response PID detector
  • Ultrafast trap heater (heating rate >160°C/second)
  • Quick check of the chromatogram peaks possible directly on-screen, without the use of a computer
  • Low memory effect allowing the automatic calibration of the analyser on a single cycle without an external PC
  • Ambient air monitoring
  • Monitoring of industrial sources emitting VOCs
  • Photochemical pollution studies (stationary and mobile laboratories)
  • Other component upon request: hexane, trimethylbenzene, i-octane, styrene…
  • Measured parameter: VOC (Benzene, Toluene, Ethylbenzene, m+p-Xylene, o-Xylene, 1,3 Butadiene)
  • Technology: Gas Chromatography
  • US-EPA Approval / QAL 1 Certification: YES
  • Measurement ranges: 0-1000 µg/m3
  • Measurement units: ppb, ppm, µg/m3 (user-selectable)
  • Lower Detectable Limit (2σ): ≤ 0.025% µg/m3 at 0.5 µg/m3 benzene
  • Noise (σ): ≤ 0.5%
  • Zero drift: ≤ 4% / 15 days
  • Span drift: < 1% / 7 days
  • Sample flow rate: 50 ml/min
  • Temperature range: 0°C to +30°C
  • Data storage: 1 year
  • Included I/O: 1LAN / 1USB / WIFI / RS232-422
  • Weight (Kg): 12.5
  • Dimensions mm (LxWxH): 483 x 606 x 133
  • Chassis: 19″ Rack, 3U
  • Power supply: ‘100~250Vac, 50/60Hz + ground

Main Options:

  • ESTEL 2 max electronic boards with:
  • 4 independent analog inputs (0-2.5 V) / outputs (0-1 V, 0-10 V, 0-20 mA, 4-20 mA)
  • 4 remote control inputs
  • 6 dry contacts
  • RS232 or RS422 serial interface (max. one Estel board if this option is used)
  • Span gas input (atmospheric pressure)
  • Span gas input under pressure (1 bar) for permanent connection to a gas cylinder

Compliance With:

  • ISO 13964, 2008/50/EC, EN14662-3:2015, EN15267-1:2009
  • EN15267-2:2009, 40 CFR PART 53 and 40 CFR PART 58
  • QAL 1 certified by the TÜV to N° 0000038507