Power Requirements: +24VDC Nominal (+18 to 32VDC)
Power Consumption: ≤ 2,4 W (depends on redundancy)
Outputs From Echo: 4-20mA (SIIS level 1),
CANopen CiA 443 (SIIS Level 2),
Digital RS-485 Modbus RTU
Power Requirements: +24VDC Nominal (+18 to 32VDC)
Power Consumption: ≤ 2,4 W (depends on redundancy)
Outputs From Echo: 4-20mA (SIIS level 1),
CANopen CiA 443 (SIIS Level 2),
Digital RS-485 Modbus RTU
Material: UNS S31803/2205 Duplex SS or Titanium
Dimensions: 20” x Ø 5” (500 mm x Ø 130 mm)
Weight in air: 13lbs (6 kg) Titanium / 19 lbs (10 kg) UNS S31803/2205 Duplex SS
Coating: Xylan 1070
ROV Handle type: D-Handle as standard (T-Handle, Fishtail handle, O-handle available)
Interface Connector type: Omnitec MKII, Tronic Connector, ODI Connector
Method of Operation: Passive acoustic
Flow Regime: Oil, Gas, Multiphase
Units of measurement: g/s
Calibration: factory calibrated
Uncertainty : ± 3 -10 % (depends on flow and calibration)
Flow Velocity: ~ 1 m/s
Particle Size: ≥ 10 μm – in gas; ≥ 20 μm – in oil
Depth: 4,500 m (14,760 ft)
External Pressure: 30 MPa
Operating Temperature: -20C to +80C ( -76F to 185F)
Pipe Surface Temperature: -100C to +290C ( -148F to 554F)
Storage Temperature: -50C to +50C ( -58F to 122F)
Design Life: 30 years
Subsea Manifolds
Subsea Jumpers
Subsea Xmas trees
Subsea Pipe spools