- Home
- Companies
- F&J Specialty Products, Inc
- Products
- F&J - Model DF-100E Series - Portable ...
F&J - Model DF-100E Series -Portable Digital Flow Meter Kit
The DF-100E Series portable flowmeter upgrade kits are designed to upgrade existing air sampling systems utilizing motors of 1/3 HP or less. The DF-100E units are connected in-line between the pump inlet and the filter holder. The DF-100E Series upgrade eliminates the need to engage in expensive conversions of equipment or the need to purchase new air sampling systems.
Most popular related searches
digital flow meter
air sampling system
flow meter
low volume air sampling
portable flow meter
flow sensor
air sampling
flow calculator
barometric pressure
filter holder
The typical operating flow ranges vary from 1 CFM to 9 CFM (30 – 255 LPM). Custom higher flow ranges with exterior mounted flow sensors are available upon request.
- Data Storage Device: (P/N: 232FCDSD)
- 2+ GB Secure Digital Card: (P/N: 372239)
- Flashcard Reader: (P/N: SDDR-199-A20)
- Display in English or metric units set at factory
- Choices of flow/volume units:
- sccm scc
- SLPM SL
- SCMH SCM
- SCFM SCF
- State of the Art microprocessor electronics
- Flowrate and volume totalizations displayed are corrected to a factory settable Reference Temperature and Pressure (4 options available)
- Classical STP 0ºC, 760 mmHg
- Normal T and P 20ºC, 760 mmHg
- Modified Normal T and P 21,1ºC, 760 mmHg
- Standard Ambient T and P 25ºC, 760 mmHg
- Elapsed time meter
- Auto zero calibration feature of flow sensor
- Bright LED display
- Flow rate accuracy within ± 4% F.S.
- RS-232 Communication Port w/Operator selectable download frequency for real-time data
- Auto Shut-off on time or volume
- DF-100: 110 – 120VAC, 50/60Hz; single phase; < 7.20 FLA*
- DF-100E: 220 – 240VAC, 50/60Hz; single phase; < 3.24 FLA*
- * FLA = Full Load Amps
- Measurement Accuracy:
- Air flow ± 4% of full scale
- Temperature ± 2.0º F (1.1º C)
- Barometric Pressure 2% over measured range
- Operating Temperatures: 0º to 122º F (-17º to 50º C)
- Storage Temperature: 0º to 158º F (-17º to 70º C)
- Calibration: Calibration-Verification once per year
- Communications Interface: RS-232 (comma delimeted text file)
- Display: LED; 6 character
- Flow calculation from differential pressure value using best-fit curve method.
- Flow correction for standard temperature and pressure
- Auto-zero correction utilizing electro-pneumatic method to compensate for offset and drift (automatic once every minute).