FALCO - Model 300 -Catalytic Oxidizer
The FALCO 300 electric catalytic oxidizer treats air streams contaminated with volatile organic compounds. The catalyst provides VOC destruction efficiencies up to 99.5%. Operation, including startup, is fully automatic. Control system accurately regulates input loading and temperatures. The controls adjust a FALCO Vapor Control Valve (VCV) to maintain safe maximum input concentrations. Automatic shutdown results if temperatures exceed limits. A spiral plate heat exchanger provides efficient heat recovery and a bypass valve allows for adjustment of heat recovery. Low heat recovery enables operation at high vapor concentration. High heat recovery minimizes energy use during operation at low input vapor concentration. At 780 ppmv (Gasoline) and 300 scfm, sufficient heat is recovered to preheat the inflow without supplementary electric energy.
- CAPACITY 100-350 scfm
- MAXIMUM INPUT LOADING 250 lb/day petroleum hydrocarbons @ 350 scfm
- VAPOR CONTROL FALCO Vapor Control Valve (VCV)
- DESTRUCTION EFFICIENCY Up to 99.5%
- CATALYST TEMPERATURE RANGE 330-620ºC (626-1148ºF)
- CATALYST Packed bed 2.5 cubic feet. Platinum and Palladium on 1/8” ceramic beads standard. Optional catalyst for chlorinated solvents
- HEAT EXCHANGER 304 Stainless steel spiral plate. 73% thermal efficiency @ 300 scfm (adjustable)
- HEATER (Electric) 56 amp @ 208 volts (20.3 kW) or, 64.6 amps @ 240V (27 kW) Solid State Control
- CONSTRUCTION Stainless steel and aluminum
- WEIGHT 830 lb. with flame arrestor
- DIMENSIONS 73" high (excluding 5` stack) X 70" long X 29" wide Fits in the back of a pick up truck.
- POWER REQUIREMENTS Heater 3Ø:
- 56 amp @ 208 VAC (20.3 kW) or 65 amp @ 240 VAC (27 kW)
- Optional:
- 33 amp @ 480 VAC (27 kW) or 38 amp @ 415 VAC (27 kW)
- Heater 1Ø:
- 56.5 @ 240 VAC (13.5 kW)
- Controls: 120 VAC, 60 Hz
- Optional: 120 VAC, 50 Hz
- APPROVALS Factory Mutual Approved for use in Class 1, Div 2, Group D, T2C Hazardous locations extending up to 41” above the ground. South Coast Air Quality Management District (SCAQMD) Certified Equipment Permit.
Packaged system includes the following:
- FALCO 300 Catalytic Oxidizer
- Airtech 15 hp, three phase, explosion proof, regenerative blower model #3BA1830
- Vapor Control Valve (VCV) with filter
- Solberg 3" inline blower filter
- Stainless steel vacuum and pressure gauges
- Vacuum relief valve
- Recirculation valve for flow adjustment
- Stainless steel mounting rails with forklift pockets
- Mounting frames, factory piping and wiring between FALCO, blower and VCV