MKS Inc.
MKS - Model MGS300-KIT -FTIR-based Continuous Emission Monitoring System Integrator Kit
FromMKS Inc.
The MGS300 system is a fully turn-key system designed to provide reliable monitoring of emissions from stationary sources, including municipal and industrial waste incinerators, power plants, cement kilns and other fixed location sources of emissions.
Most popular related searches
continuous emissions monitoring system
emissions monitoring
emissions monitoring system
continuous emissions monitoring
FTIR continuous emissions monitoring
municipal and industrial waste plant
cement industry
FTIR spectrometry
gas cell
clean air
- Measurement Technique : High resolution FTIR spectrometry
- Spectral Resolution : 0.5 cm-1
- Infrared Source : Silicon carbide @ 1200°C
- Reference Laser : Helium Neon Laser (15798.2 cm-1)
- Detector : Thermoelectrically (TE) cooled MCT (Hg Cd Te)
- Spectrometer Purge Flow : 0.2 L/min of dry N2 or CO2 free clean, dry air with dewpoint below -70°C
- Optics Purge Flow : 0.2 L/min of dry N2 or CO2 free clean, dry air with dewpoint below -70°C
- Enclosure : 19-inch rack mount chasis
- Dimensions : 17.5 in. W x 12.5 in. H x 25.5 in. D
- Power Requirements : 230 VAC/50Hz or 115 VAC/60Hz
- Weight : 50 Kg (110 lbs)
- Gas Cell Pathlength and Volume : Path Length: 5.11 m
- Fittings : 1/4 inches Swagelok®
- Mirrors : MgF2 coated mirrors
- Windows : BaF2
- O-rings : Viton®
- Operating Temperature : 5° to 40°C
- Compliance : CE