Gastec Corporation
- Home
- Companies
- Gastec Corporation
- Products
- Gastec - Model GSP-300FT-2 - Automatic ...
Gastec - Model GSP-300FT-2 -Automatic Air Sampling Pump
The Model GSP-300FT-2 has been designed small and compact air sampling pump available with an integrated flowmetre for Hand-held, Personal or site sampling. This small size air sampling pump can be possible to carry on constant flow rate for 10 hours continuous sampling. This air sampling pump employs an extremely low noise air pump and automatic shut-off air pump by preset timer or volume for integrated flow rate and accumulated time.
Most popular related searches
air sampling pump
automatic air sampling
sampling pump
air sampling
air pump
autosampling
mass flow sensor
continuous air sampling
small air pump
suction pump
- Flow volume of 50-250mL/min can be set for the inserted detector tube
- The fixed flow function automatically regulates load changes
- Real-time flow volume and integrated flow volume are automatically corrected to the values for 20ºC(68ºF)
- Automatic start enables sampling to begin after a preset time
- Automatic stop at preset time/volume, with total flow and transpired time calculations
- Ventilation system configured for uninterrupted sampling
- Compact and lightweight; 10 hrs. continuous operation on 2 AA batteries
- Specially-suited detector tubes for continuous workplace sampling (10 min.)
- Activated carbon and other solid-collecting detector tubes can be utilised
- Integrated flow rate 0 - 250 mL/min
- Real-time flow rate Parametres 50 mL/min : 0.0 - 34.5 kPa , 100 mL/min : 0.0 - 30.0 kPa
- 150 mL/min : 0.0 - 25.0 kPa , 200 mL/min : 0.0 - 21.0 kPa
- 250 mL/min : 0.0 - 16.5 kPa
- Selectable modes Timer mode: Automatic shut-off of air pump at preset time; digital display of integrated flow rate
- Fixed parametre mode: Automatic shut-off of air pump at preset volume; digital display of elapsed sampling time
- Display LC digital display (backlit)
- Real-time Flow Rate mL/min
- Integrated Flow Rate : 0.000-999.9L
- Elapsed sampling time : 0-999min
- Configuration / features Mass flow sensor (with temperature correction) and diaphragm suction pump, dustproof, splashproof construction, automatic start function, and with initial presetting circuit for maintaining a constant volume of flow
- Accuracy of real-time/integrated flow volume values Standard deviation of +/- 5%
- (for a minimum real-time flow of 50mL/min at a fixed temperature)
- Operating Temperature / Humidity range Temperature : 0 - 40 ºC(32 - 104 ºF)
- Humidity : 10 - 90 %RH (no condensation)
- Power source Alkaline dry battery AA type (x 2) allows 10 hrs. continuous operation
- Dimensions 80(W) x 40(D) x 140(H) mm
- Weight 300g(including batteries)
- Accessories Alkaline dry battery AA type (x 2), detector tube adaptors, screwdriver, black suction nipple (already attached before shipping), tube tip holder, instruction manual, etc