GrayWolf Sensing Solutions
  1. Companies
  2. GrayWolf Sensing Solutions
  3. Products
  4. GrayWolf - Model PC-3500 - Handheld ...

GrayWolfModel PC-3500 -Handheld Particle Meters

SHARE

Use the PC-3500 as a stand-alone particle meter, plug it into a sophisticated AdvancedSense®/WolfPack® system or into a mobile computer for simultaneous connection with GrayWolf’s DirectSense® probes.

Most popular related searches
  • Measures 0.3 μm to 25.0 μm
  • 0.1 CFM (2.83 LPM) flow rate
  • Long life laser diode technology
  • Measures up to 6 channels of simultaneous data
  • Approximates mass concentration in μg/m³ with density and refractive index corrections, including PM2.5, PM10 and TSP
  • Integrated handle for one-handed operation
  • Large easy-to-use icon driven color touch screen display
  • Optional, direct-connect %RH, C°/F° probe available
  • Stores up to 45,000 sample records, 1,000 sample locations and 50 recipes internally, broader options when connected to AdvancedSense®/Tablet
  • Annotation function allows user to save 32 character notations to a sample record
  • Real-Time Meter for detecting particle contamination sources
  • Easy configuration and transferable from instrument to instrument
  • Connect using RS-232, Ethernet, USB or (optional) Wireless 802.11 b/g, RS 485
  • Displays and externally prints reports for ISO 14644-1, EU GMP Annex I and FS 209E
  • Internal audible alarm
  • User-definable reports
  • User-selectable channel sizes
  • Complies with ISO 21501-4 and JIS B9921 standards
  • Seamless integration into a facility monitoring system
  • Lightweight high-impact injection molded plastic enclosure
  • 2 year warranty on instrument, except filters, 1 year on other accessories
  • The PC-3500 Handheld Particle Counter measures 0.3 μm to 25.0 μm with a flow rate of 0.1 CFM (2.83 LPM).
  • Easy to configure, this instrument displays up to 6 user-selectable size channels as well as temperature and relative humidity.
  • The PC-3500 mass concentration mode approximates density in μg/m³ and allows for density and refractive index corrections to ensure accuracy.
  • The PC-3500 counters can be controlled and monitored remotely via web browser.
  • Export data to (included) GrayWolf WolfSense® PC data-download software or view data and generate ISO 14644-1, EU GMP Annex 1 or FS 209E reports on screen or in real time through the versatile PC-3500 output options.
  • The PC-3500 meets ISO 21501-4 and JIS B9921, ensuring compliance with an onboard pulse height analyzer.
  • Size Range: 0.3 to 25|jm
  • Size Channels: Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 urn variable binning
  • Flow rate: 0.1 CFM(2.83LPM)
  • Concentration Limit: 10,000,000 Particles/ft3 @ 10% coincidence loss
  • Battery Run Time: 10 hours
  • Light Source: Long life laser diode
  • Counting Efficiency: 50% @ 0.3 um; 100% for particles >0.45 urn per JIS
  • Zero Count: <1 count / 5 minutes (<2 particles/ft3) (per ISO 2150M & JIS)
  • Count Modes: Automatic, manual, real-time meter, cumulative/differential, mass concentration, count or concentration
  • CountAlarms: 1 to 9,999,999 counts
  • Calibration: NIST traceable
  • Display: 4.3M (10.9 cm) WQVGA (480x272) color touch screen
  • Printer (Optional): External thermal printer
  • Vacuum Source: Internal pump with automatic flow control
  • Filtered Exhaust: Internal HEPA filter
  • Number of Channels: 6
  • Custom Size Channels: Calibration for custom size channels available
  • Audible Alarm: Adjustable built-in alarm
  • Battery: Removable Li-ion
  • Battery Recharge Time: 4 hours within instrument (<2 hours with external battery charger)
  • Reports: ISO 14644-1, EU GMP Annex 1, FS 209E
  • Recipes: 50 user-configurable recipes
  • Communication Modes Optional Comms Mode: RS232, Ethernet and USB Wireless 802.11 b/g, RS485
  • Environmental Sensor: Optional temperature and relative humidity probe 32° to 122°F (0° to 50°C) ±1°F (0.5°C), 15-90% ±2% relative humidity
  • Alarm: Alarms on counts for all particle sizes, low battery, sensor failure, environmental sensors and flow
  • Standards: ISO 21501-4 and JIS B9921
  • Calibration: Recommended minimum once per year
  • External Surface: High impact injection molded plastic
  • Dimensions (L x W x H): 10" x 5" x 4.5" (25.4 cm x 12.9 cm x 11.4 cm) includes handle and does not include probes
  • Weight: 2.2 lb (1.0 kg)
  • Included A ccessories: PCC-GW3500 hard-shell carrying case, quick start guide, operating manual on USB flash drive, isokinetic probe, purge filter, battery, belt clip, WolfSense PC data download software, USB cable, power supply & cable
  • Optional A ccessories: PCC-35P security case, printed manual, TRH probe, spare battery, external battery charger, external printer and isokinetic probes
  • Buffer Memory: 45,000 sample records (rotating buffer) including particle count data, environmental data, locations and times. Scrollable on screen or printout
  • Sample Locations: Up to 1,000 locations 20 characters long and 50 user defined recipes
  • Sample Time: 1 second to 99 hours
  • Power: 110 to 240 VAC 50/60 Hz universal in-line power supply
  • Operating Conditions: 41° to 104°F (5° to 40°C) / 20% to 95% non-condensing
  • Storage Conditions: 32° to 122°F (0° to 50°C) / Up to 98% non-condensing
  • Warranty: 2 years on instrument, 1 year on accessories, no warranty on filters