Advanced Geosciences Inc. (AGI)
  1. Companies
  2. Advanced Geosciences Inc. (AGI)
  3. Products
  4. PowerSting - High Powered Transmitter ...

PowerStingHigh Powered Transmitter Electrodes for High-Power Induced Polarization (IP) / Resistivity Tomograph

SHARE

y. PowerSting Transmitter Nodes make it possible to automatically inject a high power (max 3,000 V, max 12 A, max 15 kW) DC current into the ground along a survey line.

Most popular related searches

Productivity Features

  • Self-addressing: Lay them out in any order. They will figure out where they are.
  • Reversible: Both the Nodes and the cables are reversible. No need to worry if they were connected correctly.
  • eInk (bistatic display): sunlight readable and do not require power to display digits.
  • Hot-swappable: All components can be swapped at any time during the survey without loosing a data point.
  • Simplicity: Only two components: nodes and cables. All nodes and cables are identical. Should one fail you can just replace it with another.

Safety Features

  • eStop: BIG red stop button on every node. Stops current injection immediately. Universally understood stop button design.
  • Audio Warning: buzzing noise prior to current injection and during current injection
  • Visual warning:
    • 4x Ultra bright LED`s (brighter than the iPhone 6 flash) located on 4 side of node and will blink prior to current injection and during the current injection.
    • Each LED features a Fresnel optically clear light pipe with a 160 degree view angle. You can`t miss the flashing no matter what the direction you are looking at the node.
  • 15kV isolation on the sleeved banana plug and socket
  • Black/yellow safety label colors project attention from onlookers
  • ANSI Danger High Voltage Warning Label in 3 languages: English, Spanish and Chinese

Typical system setups and expected depth of penetration

  • 2.7km spread: ~500 meter depth of penetration, 28 PowerNodes, 100 meter electrode spacing
  • 4.1km spread: ~750 meter depth of penetration, 42 PowerNodes, 100 meter electrode spacing
  • 5.5km spread: ~1,000 meter depth of penetration, 56 PowerNodes, 100 meter electrode spacing

You need the following components for an tomographic RES/IP survey:

  • SuperSting
  • PowerSting
  • Sting Generator Set (SGS)
  • Switch box and passive cables (for passive cable setup), or dual-mode electrodes
  • PowerSting Transmitter Nodes and connecting cables (standard for maximum 8 Amp; special order for 12 Amp)
  • Current electrodes--sheet metal or stainless steel stakes
  • Potential electrodes--stainless steel stakes or non-polarizable electrodes

Technical Specification

  • 2,000V
  • 5 Amp
  • 10kW