Pressure: Operating Pressure: from 1.5 to 6 bar. Static resistance to pressure: 22 bar. Flow Rate: Service Flow rate (1 bar drop): 7 mc/h. Backwash: max 3 mc/h. Slow rinse: from 46 to 350 lt/h. Fast rinse: max 2,5 mc/h.
Most popular related searches
2011/65/EC regulations
RoHS regulations
drain lining
pipe fitting
drain line
conductivity monitoring
backwash
EC regulations
valve operator
RoHS
- MAXIMUM QUANTITY OF REGENERATIVE RESIN: 200 lt
- OPERATING TEMPERATURE: from 5 to 40° C
- VALVE MATERIAL: ABS + FV
- DOWNFLOW REGENERATION
- Adjustable cycles:depend on the timer
- Time available: depend on the timer
- ELECTRICAL RATE see timers
REGENERATION CYCLE
- Backwash Upflow
- Brine Downflow
- Slow Rinse Downflow
- Rapid Rinse + Brine Refill Downflow
- Servizice Downflow
DIMENSIONS
- Mounting base: 2”1/2 8UN
- Distributor pilot: Ø 32 mm
- Drain line: Ø 20 mm
- Brine line: 3/8”
PIPING FITTING IN/OUT AVAILABLE (BAYONET)
- ¾” female thread
- 1” female thread
- 1”¼ female thread
- 1”½ female thread
- Ø ISO 32 female fitting to glue
- ¾” NPT female thread
- 1” NPT female thread
- 1” ¼ NPT female thread
- 1”½ male thread
- 2” male thread
ACCESSORIES/OPTIONS
- VIRIDION system conductivity monitoring (PS1135-7)
CERTIFICATES
- DM 174 DD April 06, 2004 compliance
- 2014/30/UE (EMC) Directive
- 2014/35/UE Low tension
- 2011/65/EC (RoHS) directive
- Machine Directive 2006/42/EC