PEAK Scientific Instruments Ltd

i-FlowLabModel 6XX1 -Nitrogen Generator

SHARE

i-FlowLab is a total laboratory on-site nitrogen gas solution for customers with high flow demands or high purity applications and is capable of delivering a consistent & reliable supply of gas on-demand. Engineered based on robust PSA technology, i-FlowLab 6XX1 nitrogen generators are available in over 100 pre-configured specifications, designed to suit the full and varying demands of your facility, with flow rates ranging from 116-4253 L/min at purities up to 99.5%.

Most popular related searches

Modular & scalable, i-FlowLab is designed as a future-proof solution, with the ability to be expanded retrospectively, with the addition of CMS columns, in order to increase capacity and accommodate future growth in requirements.

i-FlowLab is an ideal complete laboratory solution for multiple applications, such as LC-MS, Sample Preparation, Gloveboxes and many more.

  • Cost effective, total laboratory nitrogen gas supply solution
  • Consistent & reliable, always available on-demand to meet application needs
  • Energy efficient, with low ongoing running costs & minimal maintenance
  • Scalable & future-proof design, with ability to expand capacity by adding more CMS columns
  • Safe and convenient, no more manual handling or on-site health & safety concerns
  • Verified industry standards compliance (EIGA, European Pharmacopoeia, JECFA & US FDA)
  • Build-in oxygen analyzer, for continuous, real time monitoring of nitrogen purity & quality
  • Optional purity safeguard, auto-bypass feature for purity critical applications
  • Take complete control of your costs & nitrogen gas requirements, by bringing your supply in-house
  • Eliminate the need for gas cylinders, LN2 dewars /micro-bulk deliveries or large bulk liquid trucking
  • Reduce your on-site carbon footprint & become a self-reliant and sustainable operation

Gas

  • Gas Type: Nitrogen
  • Min Gas Flow: 116L/min
  • Max Gas Flow: 4253L/min
  • Max Output Pressure: 130psi/9bar
  • Max Purity: 99.5%

Site & installation

  • Max Inlet Pressure: 145psi/10bar
  • Min Air Inlet Flow: Dependent on required flow rate
  • Min Inlet Air Quality: ISO 8573-1:2010 Class 1.4.1
  • Start Up Time: Dependent on model
  • Power Consumption: 250 Watts
  • Voltage: 100-230 ± 10% VAC
  • Frequency: 50 / 60 Hz
  • Current: 2.0-1.0 Amp
  • Max Operating Temp: 50°C / 122°F
  • Particles: <0.01µm
  • Noise Level: 59dBa @1m
  • Accreditations: CSA, CE

Dimensions & weight

  • Size (HxWxD) mm: 1738 x 500 x 760 mm
  • Size (HxWxD) Inches: 68.4 x 19.7 x 29.9 inches
  • Generator Weight: 197kg / 433.4lbs
  • Service requirements

Annual maintenance

  • Annual O2 analyzer calibration (optional)
  • Replace O2 analyzer every 4 years

General

  • Expand to meet demand: i-Flow Lab can be expanded to include up to 10 banks. Each bank is 160mm (6.3") and total depth of a 10 bank system including the i-FlowLab system is 2200mm (86.61").