ENVEA - Model LAS 300 XD -In-Situ Cross-Duct TDLAS Analyzer
FromENVEA
TDL monitor for in-situ non-invasive measurement of NH3 & H2O, HCl & H2O, HF as well as low or high concentrations of CO and O2 in process or CEMS applications. The Tunable Diode Laser Spectroscopy (TDLS) is the perfect technology to use when you are looking for a selective measurement and a fast response time on some gas components as NH3, HCL, HF or even O2 when conditions are too rough for standard O2 Zirconia In-Situ analysers.
Most popular related searches
total sulfur analysis
carbon monoxide monitor
Oxygen (O2) monitoring
tunable diode laser
carbon monoxide monitoring
gas monitoring
cement industry
hydrochloric acid
EN 15267
HF monitor
- Available versions:
LAS 300XD NH3 for ammonia (NH3) and water (H2O) monitoring
LAS 300XD CO for low and high concentration carbon monoxide (CO) monitoring
LAS 300XD HCl for hydrochloric acid (HCl) and water (H2O) monitoring
LAS 300XD HF for hydrofluoric acid (HF) monitoring
LAS 300XD O2 for oxygen (O2) monitoring - Suitable for harsh environment; sensor unaffected by contaminants (no corrosion)
- Absence of extractive conditioning: eliminates errors related to sample handling
- Absolute measurements: no drift, no calibration, linear response
- Very low maintenance, low cost of ownership
- In-situ & non-invasive measurement (optical technique)
- Interference free gas measurements
- Large dynamic range
- Compact system
- Real-time – 1s response
- High sensitivity – ppb, ppm and % concentrations
- No sample lines required, eliminating errors due to gas sampling
- Scrubber technology
- Combustion control
- Chemical industry
- Fertilizer plants
- Waste incinerators
- Cement industry
- Glass industry
- Pulp and paper
- Biomass boilers
- Petrochemical industry
Measurable parameters
Pollutant: Range (ppm)
- HCI: 0-10 / 3000
- HF: 0 / 100
- CO: Low: 0-500 / High: 0-1-100%
- NH3: 0-15 / 500
- H2O(%): 0-5 / 50
- O2(%): 0-10 / 100
Lowest / Highest available ranges (may vary with your site conditions to be indicated on the Site Survey Form)
Technical Specifications
- QAL1 to EN 15267-3 certified: N/A
- US EPA compliance: N/A
- Sampling technology: In-Situ
- Sample transfert: N/A
- Back flush function: YES (Purge)
- Span injection: Optional: In Line Cell on receiver
- Built-In O2 option: NO
- Serial link communication: Modbus RTU
- Other Communication: NO
- Analogue OUTPUTS: YES (x 2)
- Analogue INPUTS: YES (x 2)
- Dimensions (mm): 2 x Compact enclosures: 170 x 243 x 209 mm (L x W x H) each
Complete system would normally comprise of:
- Transmitter and receiver units
- 2 alignment flanges DN50 PN16, 2’’ – 150 lbs, Class 150 (other available)
- 2x Analog inputs/outputs
- 2x Relay contacts
- Modbus RTU RS485
- LaserTool® software