MetrohmModel SPELEC VIS-NIR - SPELEC1050 -Instrument for Performing Spectroelectrochemical Measurements (350-1050 nm)

SHARE

SPELEC1050 is an instrument for performing spectroelectrochemical measurements. It combines in only one box a Lightsource, a Bipotentiostat/Galvanostat and a Spectrometer (VIS-NIR wavelength range: 350-1050 nm) and includes a dedicated spectroelectrochemical software that allows optical and electrochemical experiments synchronization.

Most popular related searches
  • Operating modes: Bipotentiostat ; Potentiostat ; Galvanostat
  • PC interface: USB
  • Power: 12 V DC
  • Potential range in volt: ±4V
  • Maximum current in Ampère: ±40 mA
  • Number of current ranges: 8
  • Number of current ranges remarks: ±1 nA to ±10 mA
  • Number of potential ranges (galvanostat): 2
  • Number of potential ranges remarks (galvanostat): ±100 mV to ±1 V
  • Multichannel instrument: NO
  • Maximum number of channels: 1
  • Maximum number of WE sharing AUX and REF: 2
  • Potential accuracy: ±0.2%
  • Current accuracy: ≤0.5% of current range at 100 nA to 10 mA
  • Potential resolution: 1 mV
  • Current resolution: 0.1% of current output range
  • Measured potential resolution: 0.012 % of potential range
  • Measured current resolution: 0.025 % of current range
  • Spectrometer (SPM) Detector: Linear silicon CCD array
  • SPM Pixels: 2048
  • SPM Pixel size: 14 µm x 200 µm
  • SPM Pixel well depth: 62,500 electrons
  • SPM Wavelength range: 350-1050 nm
  • SPM Optical resolution: 0.3+10.0 nm FWHM
  • SPM Signal-to-noise ratio: 250:1 (at full signal)
  • SPM A/D resolution: 16 bit
  • SPM Dark noise: 50 RMS counts
  • SPM Dynamic range: 8.5 x 10 rised to 7 (system) ; 1300:1 for a single acquisition
  • SPM Integration time: 1 ms to 65 seconds
  • SPM Stray light: ≤0.05 % at 600 nm; <0.10 % at 435 nm
  • Light Source (LS) wavelength range: 215-400 nm (deuterium) ; 360-2500 nm (tungsten halogen)
  • LS Stability: 1.0% peak-to-peak (over 4 hours) after 30-minute warm-up
  • LS Time to stable output: 10 minutes (deuterium) ; 1 minute (tungsten halogen)
  • LS Ignition delay: <2.0 seconds (delay for cold start-up may be longer)
  • LS Bulb life: >1,000 hours @ 240 nm (time) ; < 50% @ 240 nm (decrease of intensity) ; Continuous operation (testing conditions)
  • LS Fiber optic connector: SMA 905
  • Dimensions: 24 x 11 x 25
  • Weight of the instrument in kg: 1.95