- Home
- Companies
- Endress+Hauser Group Services AG
- Products
- Liquitrend - Model QMW43 - Liquid ...
Liquitrend - Model QMW43 -Liquid Analysis Physical Medium Properties
The Liquitrend QMW43 is developed for the food and beverage industry to help customers to ensure product safety, improve quality and increase the availability of installations. Base your decisions on the unique and reliable measurement of buildup thickness and conductivity via the combination of conductive and capacitive measuring modes.
- Reliable, repeatable and accurate measurement of buildup thickness and conductivity regardless of media type
- Conductive as well as capacitive measuring cycles, the device automatically detects the most accurate measuring mode and uses it automatically
- Verification of cleaning status without the need to open the tank
- Compact and flush-mounted stainless-steel sensor offers the perfect insight into the conditions in pipelines or tanks at all critical locations
- Plug and Play - simple commissioning without presettings
- Hygienic safety by Design and material traceability are a matter of course
- Integrated digital communication option via IO-Link
- Cleaning optimization, blending homogeneity monitoring and media differentiation of liquids, suspensions, pasty media etc.
- For the use in storage, mixing and process vessels with or without an agitator, pipes and equipment periphery
- Process connections: Threads and hygienic connections
- Sensor design: Flush-mounted, surface roughness Ra<0.76µm
- Temperature: -20 to +100°C (-4 to +212°F), CIP/SIP to 150°C (302°F) for 1 hour
- Certificates and declarations: 3A, FDA, EHEDG and EG1935/2005, EN10204- 3.1
Measuring principle
Medium consistency/ Build-up measurement
Measuring method
Capacitive- conductive
Application
Continuous inline measurement of build-up and liquid conductivity
Supply voltage
10…30 VDC
IO-Link: 18…30 VDC
Measurement range
Conductivity:
0 µS/ cm...100 mS/ cm
Build-up thickness:
0 mm…10 mm
Accuracy
Build-up:
<= 1% of measuring range
Conductivity:
0...2 mS/ cm: <= 5% of reading
2...20 mS/ cm: <= 7% of reading
20...50 mS/ cm: <= 10% of reading
50...100 mS/ cm: <= 15% of reading
Ambient temperature
-40°C…+70°C (-40°F...+158°F)
Process temperature
-20°C…+100°C
(-4°F...+212°F)
+150°C (+302°F) for 1h
Process pressure
Vacuum...25 bar
(Vacuum...362.5 psi)
Output
4...20 mA
Frequency
IO-Link
Connection
Threads G1", G3/4", M24,
Tri-Clamp ISO2852, DIN11851
Ex certification
No Ex certificates
CSA C/US General Purpose
Additional certifications
EN10204- 3.1
EHEDG
3-A
EG1935/2004
CRN approval
Options
Customer specific configuration
Cleaned from oil and grease
Surface roughness test
Welding- and process adapters