All ADVANTAGE LITE load points include these features:

  • Each pre-assembled load point provides a choice of stainless steel mounting hardware and a C2 compatible stainless steel, matched, and sealed load sensor to resist corrosion and provide years of dependable performance.
  • Its rubber element mount provides stray voltage isolation, minor misalignment correction, thermal expansion and shock absorption. It is designed for use in applications with conveyors and vessels with or without agitators or mixers.
  • The load point assemblies are selfchecking, eliminating the need for costly external check rods to hold the assembly in place. Lift-off protection is built-in.
  • The orientation of the load point assembly is non-restricted. This means its positioning is not limited to one or two directions, enabling you to install it in tight areas with very little clearance, without affecting its performance.
  • Each load sensor comes with twenty feet of six-conductor cable and a color-coded wiring label to aid in installation. The performance characteristics of the load sensor are also stored in an internal memory device. A Hardy Instruments C2 certified controller uses these parameters, its internal characteristics and a reference point to electronically calibrate the system. C2 calibration reduces downtime for installation and repairs, while eliminating the need and cost for heavy test weights, that can lead to delays and weight handling related injuries.
  • Pre-assembled for quick installation.
  • All Stainless Steel to resist corrosion and provide years of dependable performance.
  • C2 Electronic Calibration provides quick electronic system calibration without test weights.
  • Mounting hardware for accuracy and durability:
  • Mount provides self-centering, which allows your vessel to expand and contract while the load isapplied to the same point on the sensor. This helps provide consistent and superior accurate weight signals.
  • A rubber element mount provides stray voltage isolation, minor misalignment correction, thermal expansion and shock absorption.
    Matched performance: each sensor is calibrated for both voltage and current, so it responds like another sensor at the same capacity in the family.
  • Exceptional Value: features and quality at an affordable price.
  • ADVANTAGE LITE compression load cells are available in capacities of 440, 1.1k, 2.2k and 4.4k lb. and can be used in applications such as tank, hopper and vessel weighing, process measurement and batch weighing. Each ADVANTAGE LITE load cell includes 20 feet of cable.
  • Tank, Hopper, and Vessel Weighing
  • Process Measurement
  • Batch Weighing
  • Rated Output (ES): 2±0.004mV/V
  • Non-Linearity: <±0.025 % R.O.
  • Hysteresis: < ±0.025 % R.O.
  • Zero Balance: <±1.0 % R.O.
  • Creep @ 5 Min.: <±0.010 % R.O.
  • Temp Effect Output: <±0.002 % R.O./C
  • Temp Effect Sensitivity: <±0.002 % R.O./C
  • Input Resistance: 1146 ± 4.36% ohm
  • Output Resistance: 1001 ± 1.0% ohm
  • Insulation Resistance: >5000 Mohm
  • Excitation: 5 - 15 vdc
  • Safe Load Limit: 150 % Emax
  • Ultimate Load: >150 % Emax
  • mV/V/ohm: 0.002 ± 0.1%
  • Warranty: Two years