SST Sensing - a brand by Process Sensing Technologies (PST)

LuminOxOptical Oxygen Sensors

SHARE

The low cost, low power and long life are what differentiates the LuminOx Optical Oxygen Sensors from other oxygen sensors. Developed and manufactured by SST, the LuminOx family is a range of factory calibrated oxygen sensors which measure ambient oxygen levels using luminescence-based optical technology. Oxygen sensing using this sensor enables oxygen concentration to be calculated. The patented technology allows SST to produce a sensor that provides low power operation, while offering a much longer lifetime than electrochemical and galvanic sensors.

Most popular related searches

The LuminOx Optical Oxygen Sensors are internally temperature compensated meaning the customer does not need to consider this in their design. It also communicates directly to the customer’s UART so no signal conditioning circuitry is required.

LuminOx is a completely solid state sensor and contains no lead or liquid electrolytes. It is therefore 100% RoHS compliant. It also has virtually no cross sensitivity, allowing it to be used in applications where other technologies are unreliable due to the particular mix of gases present.

LuminOx measures the partial pressure of oxygen (ppO2) which, along with the internal sensor temperature is communicated serially to the host microcontroller. LuminOx is also available with an internal barometric pressure sensor. This enables oxygen concentration (%O2) to be calculated and transmitted, along with the ppO2, temperature and barometric pressure.

FEATURES

  • Luminescence–based optical technology, NOT electrochemical
  • Several configurations - standard, sealed base, flow through
  • Factory calibrated, temperature & pressure compensated
  • Connects directly to a microcontroller without any additional circuitry
  • Compact footprint
  • Maintenance free
  • Contains no hazardous materials

BENEFITS

  • Low power, long life due to non-depleting sensing principle
  • Able to meet alpplication specific requirements
  • Accurate operation over a wide environmental range
  • Easy to install
  • Ideal for applications where space is limited
  • Low cost
  • RoHS & REACH compliant
  • Supply Voltage (Vs): 5VDC (4.5VDC min. —5.5VDC max.)
  • Supply Current (Is): <7.5mA (streaming one sample per second) <20mA Peak
  • Output Type: 3.3V TTL level USART (5V tolerant)
  • Operating Temperatures: +10°C to +45°C
  • Storage Temperatures: -30 to +60°C
  • Humidity: 0-99% Rh (non condensing)
  • Barometric Pressure Range: 500-1200mbar

OUTPUT VALUES

  • Oxygen Range: 0-25% O2
  • Oxygen Pressure Range: 0-300mbar ppO2
  • Response Time: T90 <30s (typical)
  • Accuracy:  
    • ppO2: <2% FS
    • Temperature: Indication only
    • Pressure: ±5mbar
    • O2: Determined by ppO2 & pressure accuracy
  • Resolution:  
    • ppO2: 0.1mbar
    • Temperature: 0.1°C
    • Pressure: 1mbar
    • O2: 0.01%
    • Lifetime: >2 years