Zero Gravity Filters Inc.
- Home
- Companies
- Zero Gravity Filters Inc.
- Products
- ZGF - Model MG600 - Maggie Magnetic ...
ZGF - Model MG600 -Maggie Magnetic Separator 6-Core
Body: 5” Stainless steel 304L. Magnet: Permanent, rare earth, neodymium iron boron. Magnetic tube: Stainless steel 316L. Ball Valve: Outlet/Purge: 1.25” 3-way ball valve. The valve has a stainless steel 316 body and ball with PTFE seats. Actuator Double acting, developing 601 in/lb at 80 psi. Manufactured by Assured. Automation, size PD090. Connections: Inlet: 1.25” Victaulic. Outlet/Purge: 1.25” FNPT. O-rings Viton standard.
Most popular related searches
3 way ball valve
magnetic separation
ball valve
rare earth
solenoid valve
magnetic tube
air valve
rare earth magnet
stainless steel tube
backwash
Controls
- Electrical Timer Adjustments for purge duration and purge interval between 10ms and 99 hours.
- Manual purge push button. Housing made of ABS plastic, NEMA 4 (IP65) rated.
- Air Solenoid Valve ASCO direct mount 24 VDC or 120 VAC
- Air Manifold Block Aluminum
Site Requirements
- Air Supply 70 to 80 psi, clean and dry. ¼” air supply connection. Required air flow is 32
- standard cubic feet per minute (scfm).
- Electrical Supply 24 VDC or 120 VAC
- Pneumatic Pipework ¼” pneumatic flexible tubing with push-in connectors
- Approximate Dimensions and Weight
- 13 x 12” x 36”.
- Dry: 147 lbs, Wet: 159 lbs (67/72 kgs)
- Fluid Volume 1.25 gallons
Operating Parameters
- Number of Magnetic Shuttles 6 per unit.
- Flowrate
- 70 gpm (265 LPM), maximum with water-based fluids.
- 50 gpm (190 LPM), maximum with oil (30 cSt at 40ºC).
- Operating Pressures 100 psi (690 kPa), maximum. 25 psi (172 kPa/0.17 mPa), minimum. 150 psi (1,035 kPa) test pressure
- Operating Temperature 170ºF (75ºC) maximum.
- Backwash Control Automatically using electrical timer or manually using push button.
- Energy Consumption (per purge) Air: .66 cubic feet (rotate valve and shuttle Maggie)
- Electrical: 2.5 watts
- Purge Volume ~6 gallons (5 seconds at 70 gpm)