microtuf - Model FS42CS -Basic Mass Flow Switch
Thermal Differential Mass Flow Switch for the detection of the mass flow rate of liquids and gases. Wide operating temperature range -100°F to +850°F (-70°C to +458°C). Wide flow range of .01 to 5 feet per second (fps) in oil, 2.5 fps in water and .1 to 500 fps in gases. Two year workmanship warranty. Removable Plug-in electronics. Free of all moving parts that can stick, coat or fail. Fast response time of .5 to 10 seconds depending on the media. Self heating sensor design improves repeatability. No separate heater to fail or slow response time. Optional Glass window (XW).
- Analytical Sample Confirmation
- Air Handling System Monitor
- Sanitary Cleaning System Monitor
- Fire Suppression System Monitor
- Heat Transfer Fluid Monitoring
SENSORS
Type:
Thermal Differential, Dual RTD Sensors
Process Connection:
Standard 0.75 inch MNPT
Optionally 0.5 inch and larger MNPT and various other process connections such as sanitary and flanges
Insertion Length:
Standard 2.0 inch
Optionally 0.5 inch or greater
Operating Temperature Range:
Standard -100°F to 390°F (-70°C to +200°C)
Medium Temperature to +572°F (+300°C)
High Temperature to +850°F (+458°C)
Materials of Construction:
Standard 316L Series Stainless Steel
Optionally Hastelloy, Monel, Inconel and other exotic
materials
Operating Pressure Range:
Standard to 3000 psia (207 bar)
ELECTRONICS
Power:
Standard 110VAC Optionally 220VAC, or 24VDC at 3 watts (No heater power required)
Operating Temperature Range:
Standard -40°F to +140°F (-40°C to +60°C)
Optionally remote electronics for use in medium and high temperature environments
Outputs:
DPDT Relay contacts rated at 5 amp, 250 VAC with fail safe capability
Self-Test:
Integral and Automatic during power up.
Enclosure:
Explosion proof; NEMA 3, 4X, 7, and 9; CSA, FM, and UL, approved
INSTRUMENT
Operating Range:
Adjustable Flow Rate (feet per second – fps), typical: 0.01 to 5.0 fps oil, 2.5 fps water and 0.1 to 500 fps gases.
Response Time:
Sensor response time 0.5 to 10 seconds media dependent
Stability:
Drift < .5% from calibrated setpoint over a range of ±50°F. Temperature compensated throughout entire range.
Repeatability:
±1% of setpoint
Available Approvals:
CE, CSA, Class 1 Div. 1 Groups B, C, & D