AMACS Process Tower Internals

AMACS MistFixMist Eliminator

SHARE

Our patented MistFix® Insertion Mist Eliminator was developed specifically for retrofit applications where the existing vessel had no mist eliminator support and/or no internal access. We found that the oil and gas industry had a large number of vertical gas Knock Out Drums that were designed to run at relatively low gas rates and had no internals to promote mist elimination. Over time, plant capacities were increased feeding more gas into the drum than was originally considered.

Most popular related searches

This resulted in increased liquid carryover and these empty KO Drums became a bottleneck. The drums required an effective mist eliminator to increase the capacity. Without the MistFix® Mist Eliminator, the only solution is to cut apart and re-weld the vessel shell, which will often require extended down time for field work, post weld heat treatment, re-certification and a re-paint. The MistFix® Mist Eliminator installs without modification to the existing vessel. It drops into the top gas outlet nozzle and hangs from the flange. We recommend a minimum of 8” nozzle diameter. We have used MistFix® Mist Eliminator on both vertical and horizontal drums but note that the gas outlet nozzle must be vertical.