Model FGC-1010 -Gas Chromatograph

SHARE

Determination of volatile organic compounds in water (drinks), detection of alcohol content in blood, indoor air pollutant detection (TVOC), analysis of liquor flavor components, transformer oil analysis, detection of residual solvents in pharmaceuticals, analysis of high purity gases, residues in medical equipment Determination of ethylene oxide. The main units of chromatograph are: liquor factory, other wineries, petrochemical, liquefier gas plant, coal industry, environmental testing, testing station, judicial appraisal center, public security system, food factory, quality inspection department, water supply factory, pharmaceutical factory, Pesticide plants, gas plants, chemical plants, packaging plants, paint plants, honey factories, chemical industry and other major chemical components, etc. need to use gas chromatograph, liquid chromatograph.

Most popular related searches
  • Large screen LCD Chinese display. Easy to learn and easy to learn.
  • With self-diagnosis, over-temperature power-off protection, file storage, call, fifth-order program temperature and other functions, with single-column automatic compensation function; can ensure the stability of the baseline during temperature-programming analysis.
  • The instrument is equipped with three packed columns, three columns of capillary columns, and three independent gas channels.
  • With six independent temperature control areas, the intelligent door opening system has a very fast cooling speed; each gasification chamber, detector and amplifier are modular in design, and the installation and replacement are very convenient.
  • Equipped with a separate capillary analysis system, separate capillary split injector (including diaphragm cleaning, splitting and makeup adjustment). Optional capillary split/splitless injectors are available.
  • The instrument is equipped with five detectors: hydrogen flame detector, thermal conductivity detector, flame photometric detector, electron capture detector and nitrogen and phosphorus detector. Three detectors can be installed at the same time. Users can choose according to their own analysis requirements. It is also possible to increase the injection of the six-way valve, the reformer unit, etc.; and to realize the series and parallel operation of the detector.

Temperature control index

  • Temperature control area: column box, sampler, detector
  • Temperature control range: 5 °C ~ 450 °C (increment 1 °C) at room temperature
  • Temperature control accuracy: better than ± 0.1 °C
  • Program temperature: Eight-order rate 0.1 ° C ~ 40 ° C / min (increment 0.1 ° C)