- Home
- Companies
- Hardy Process Solutions
- Products
- Model HI 2204 - Strain Gauge Weight ...
Model HI 2204 -Strain Gauge Weight Transmitter
The Hardy HI 2204LT comes sealed and potted to withstand typical industrial environments. It has a course zero offset adjustment to remove dead load, a fine zero adjustment to compensate for small differences between load cells/ points, and a span adjustment to set the operating range for the “live load.”
The transmitter produces a current limited, 5 VDC excitation voltage which powers the load cell/point momentarily at the rate of about 90 times per second and converts the signal read into a 4-20 mA output. The transmitter is used primarily in level by weight and force measurement applications.
The HI 2204LT is capable of developing its full 4-20 mA signal while requiring a "live load" of only 33% of the total load cell capacity. This is true even when four 3 mV/V, 350 ohm load cells/points are used.
The transmitter is available mounted in either an optional NEMA 4 rated painted steel (-A3) or NEMA 4X rated stainless steel (-A5) summing junction box for multiple load cell systems.
An intrinsic barrier assembly model HI 705IBA is available for using the HI 2204LT transmitter in a safe environment with the systems load cells in a hazardous rated environment.
HI 2204LT Loop Powered Level Weight Transmitter
The HI 2204LT is designed for use in nonhazardous environments. It produces a 5 VDC excitation voltage. The HI 2204LT is capable of eveloping its full 4-20 ma signal while requiring "liveload" of only 33% of total load cell capacity. This is true even when four 3 mV/V, 350 ohm load cells/points are used.
- Two Wire Transmitters
- Powers up to 4 Load Cells/Points
- Adjustable Span and Zero
- FM approved - Class l, Div. 1 (HI 2201LT only)
- Two Year Warranty
Process Weighing
- Level-by-Weight
- Force Measurement
Loop Power
15 to 50 volts DC across the transmitter
15v minimum would be with 0 ohm load; add 20 millivolts per ohm to the minimum loop voltage
25v minimum loop voltage required for a 500 ohm load
Linearity
0.08% of full scale
Response Time
250 milliseconds
Sensitivity
3 mV/V full scale with adjustment to 1 mV/V
Zero Fine Adjustment
Approximatley 1% of full scale
Power Supply Rejection
0.1% from 15 to 50 v
0.015% from 20 to 30 v
Load Cell Excitation
5 VDC (Pulsed)
Temperature Range
0 to 60° C
Temperature Coefficient
0.025% per degree C
Ripple
10 mV p-p at 20mA into a 500 ohm load
Approvals HI 2201LT
CE
FM, Class l, ll & lll, Div 1 Groups A, B, C, D, E, F & G
Approvals HI 2204LT
CE
Warranty
Two-year warranty against defects in workmanship
Accessories
NEMA 4, Pointed Steel
Junction Box or Summing Box
NEMA 4X, Stainless Steel
Junction Box or Summing Box
NEMA 4X, Fiberglass
Junction Box or Summing Box
Snap track and Adapter