ENVEAModel MIR 9000 CLD -Multi-Gas NDIR-GFC Analyzer

FromENVEA
SHARE

Standard Reference CLD method for low & ultra low NOx measurement, IR-GFC for CO, CO2, SO2, N2O, Nox, HF, HCl, TOC and O2 in a single analyzer.

Most popular related searches

Multi-Gas IR-GFC analyzer (Infrared Gas Filter Correlation) with CLD option (Chemiluminescence Detector) designed to measure dry and corrosive samples

  • Over 4000 installations worldwide, covering many applications and industries
  • Unheated sample line thanks to the permeation drying technology used
  • Intrinsic security with on-board residual H2O measurements
  • On-board oxygen measure for environmental reporting
  • Interactive menu-driven software with real time graphic display for ease of operation
  • Highly accurate, excellent stability with automatic optical stability check
  • Automatic CO2 and cross interference correction
  • Built-in data logger for 7 additional parameters (flow, pressure, temperature or any other analogue input)
  • Compatible with various drying technologies such as a SEC sampling system or a high performance gas cooler
  • Cogeneration, Gas Turbines
  • Industrial Boilers
  • Furnaces
  • Power & Combustion

Measurable parameters
Pollutant: Range

  • HCI: 0-15 / 5000
  • HF: 0-25 / 300
  • NO: 0-20 / 2000
  • NO2: 0-20 / 2000
  • N2O: 0-20 / 2000
  • NOx: 0-20 / 2000
  • SO2: 0-75 / 5000
  • CO: 0-75 / 10000
  • CH4: 0-10 / 1000
  • THC: 0-50 / 5000
  • CO2(%): 0-10 / 100 or 0-20
  • O2(%): 0-10 / 25

Lowest / Highest available ranges expressed in mg/m3 (may vary with your site conditions to be indicated on the Site Survey Form)

Technical Specifications

  • QAL1 to EN 15267-3 certified: YES
  • US EPA compliance: YES
  • Sampling technology: Cold/Dry Extraction
  • Sample transfert: non heated polytube
  • back flush function: YES
  • span injection: YES on analyser or at sample point
  • Built-In O2 option: YES
  • Serial link communication: RS232 / RS422
  • Other Communication: Ethernet
  • Analogue OUTPUTS: Optional
  • Analogue INPUTS: YES (x 4)
  • Dimensions (mm): • Tight box: 200 x 600 x 600 (D x W x H)
  • • 19” rack: 490 x 483 x 177 (D x W x H)

Complete system would normally comprise of:

  • Sample extraction and conditioning probe (with integrated temperature, pressure and flow measurement)
  • Cold sample lines
  • Calibration module
  • Instrument air drying module
  • Acquisition and data management system (DAHS) may complement the system

      COMPLIANCE WITH LCPD AND WID APPLICATIONS

  • QAL 1 certified by the MCERTs to EN 15267-3
  • QAL3 compliance as defined by EN 14181
  • U.S. EPA approved as compliant with 40 CFR 60 ET 75