Ambest Electronics (Ningbo) Co Ltd

Numens - Model 400-001 -non-addressable carbon monoxide (CO) Gas Alarms

SHARE
400-001 series non-addressable carbon monoxide (CO) gas alarms are suitable for connection to 2-wire non-addressable fire detection control and indicating equipment. 400-001 detectors can also connect to addressable fire detection control and indicating equipment that can accept non-addressable detectors . Advanced electronics in conjunction with a semiconductor gas sensor provide early detection of carbon monoxide gas and high immunity against unwanted alarms. The 400-001 CO alarm range provides fire detection and alarm system designers with a Standards-compliant, economical gas detector for life safety and property protection applications.
Most popular related searches

·          Advanced algorithms provide advanced detection discrimination

·          Stable gas sensing chamber. No adjustment or replacement required

·          High immunity against unwanted alarms

·          Surface-mount device (SMD) circuit board design

·          2-wire models

·          Detector auto-reset once gas levels fall below alarm threshold levels

·          Magnet-initiated alarm test function

·          Audible warning signal of an internal fault

·          Easy installation. No programming required

·          Connectable to zone monitor for use with addressable control and indicating equipment

·          Sleek, low-profile housing design

·          Low maintenance

 

 

400-001

Operating voltage

DC (10.8 ~ 33) V

Start-up current

≤ 100 ÂµA

Start-up time

≤ 10 min

Quiescent current

50 ÂµA

Quiescent condition indicator

Flashingred LED every 5 s

Alarm current (max)

50 mA

Sampling time

(2 ~ 4) s

Alarm response threshold

70 ÂµL/L for 60 min ~ 240 min a

150 ÂµL/L for 10 min ~ 50 min a

400 ÂµL/L for 4 min ~ 15 min a

 

50 ÂµL/L for 60 min ~ 90 min b

100 ÂµL/L for 10 min ~ 40 min b

300 ÂµL/L for < 3 min b

Alarm condition indicator

Continuous red LED

Reset voltage

≤ 1 V

Reset time

≤ 10 s

Auto reset time

< 30 s

Internal fault indication

Single short audible signal every 30 s

Operating temperature

(-10 ~ +40)°C

Operating humidity

(0 ~ 95)% RH, non-condensing

Storage temperature

(-25 ~ +70)°C

Storage humidity

(0 ~ 98)% RH, non-condensing

Dimensions (excluding contacts)

Φ 99 mm Ã— 45 mm

Ingress protection rating

IP-42

a Complies with UL 2075, Gas and Vapor Detectors and Sensors.

b Complies with EN 50291, Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements.

 

EN 50291 a, c

UL 2075 b, c

CE

400-001

         √             √

√

400-002

√

√

√

400-003

√

            
             √

√

a EN 50291 Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements

b UL 2075 Gas and Vapor Detectors and Sensors

cThird-party conformance assessment has not been undertaken.