Ambest Electronics (Ningbo) Co Ltd

Numens - Model 401-001 -non-addressable ultraviolet flame detector

SHARE
The 401non-addressable ultra-violet flame detectors are suitable for connection to 2-wire and 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept non-addressable type detectors . The 401 UV flame detectors are suited to applications where flames rapidly develop due to thenature of the combustible materials, such as where petrochemical products are used or stored. The 401UV flame detector provides fire detection and alarm system designers with a Standards-compliant detector for life safety and property protection applications.
Most popular related searches

The 401non-addressable ultra-violet flame detectors are suitable for connection to 2-wire and 4-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept non-addressable type detectors[1].

The 401 UV flame detectors are suited to applications where flames rapidly develop due to thenature of the combustible materials, such as where petrochemical products are used or stored.

The 401UV flame detector provides fire detection and alarm system designers with a Standards-compliant detector for life safety and property protection applications.



[1]May be used with the 620-001 detector monitor module.

 

401-001

401-002

401-003

401-004

Operating voltage

DC (10.8 ~ 33) V

DC (10.8 ~ 26.4) V

Start-up current

≤ 100 ÂµA

Start-up time

≤ 30 s

Quiescent current

30 ÂµA

Quiescent condition indicator

Dual flashing red LED

Alarm current (max)

50 mA

30 mA

40 mA

Sampling time

(4 ~ 6) s

Alarm condition indicator

Dual red LEDs

Reset voltage

≤ 1 V

Reset time

≤ 5 s

Field of view

120°cone

UV sensitivity

(185 ~ 260) nm

Alarm response (typical)

30 mm gas flame at 4 m within 10 s

Alarm relay

—

SPST. N/O. 1.0 A @ DC 30 V / 0.5 A @ AC 125 V

Auto reset time

—

< 30 s

Operating temperature

(-10 ~ +55)°C

Operating humidity

(0 ~ 95)% RH, non-condensing

Storage temperature

(-25 ~ +80)°C

Storage humidity

(0 ~ 98)% RH, non-condensing

Dimensions (excluding contacts)

Φ 102 mm Ã— 45 mm

Ingress protection rating

IP-42

 

EN 54-10a, b

CE

401-001

√

√

401-002

√

√

401-003

                  √

√

401-004

√

                   √

a EN 54-10 Flame detectors – point detectors

b Third-party conformance assessment has not been undertaken.