Core Sensors LLC
  1. Companies
  2. Core Sensors LLC
  3. Products
  4. Core Sensors - Model CS54 - ...

Core SensorsModel CS54 -Non-Incendive Differential Pressure Transducer

SHARE

The CS54 Non-Incendive Differential Pressure Transducer is a high strength sensor designed for differential pressure measurements of liquids and gases in Class I, Division 2 hazardous locations. A 316L SS oil filled sensor element provides excellent stability over a wide operating temperature range while offering corrosion resistance against various liquids and gases. Differential pressure ranges up to 50 PSI are available with 1/4″ MNPT or FNPT process connections.

Most popular related searches
  • CSA Class I, Division 2, Groups A, B, C, D T4 Approved
  • Differential pressures from 1 PSI up to 50 PSI
  • Line pressures up to 500 PSI
  • Bi-directional pressure ranges available
  • Assembled in New Jersey, USA
  • Filtration
  • Cryogenic bulk tank level measurement
  • Compression systems
  • Test stands

Available With A Turck Minifast Connection
In an effort to simplify installation in Class I, Division 2 hazardous locations, the CS54 Non-Incendive Differential Pressure Transducer is offered with an integral Turck Minifast electrical connection.

When combined with a CSA Division 2 approved Turck cordset and a Turck Lokfast Guard, there is no requirement for conduit to be installed over the cable*. This not only makes installation easy but also makes switching out sensors less cumbersome. Core Sensors can supply all components as a complete package. Click here to learn more about the Turck Minifast electrical connection.

Performance

Accuracy @ 25°C*
≤ ± 0.25% BFSL
≤ ± 0.5% BFSL (2 PSI & below)

Stability (1 Year)
≤ ± 0.25% of FS

Pressure Cycles
4 million

Max Line Pressure**
500 PSI

Max Differential Pressure
50 PSI

Overpressure***
2X or 500 PSI, whichever is less, configured differential pressure

Burst Pressure***
3X configured differential pressure

* Accuracy includes non-linearity, hysteresis and non-repeatability
** Max line pressure is the highest common mode pressure that can be applied to the sensor without damage.
*** Overpressure and burst pressure are the maximum differential pressure that can be applied to the high or low side before damage to the sensor will occur.

Thermal

Operating Temperature
-40 to +80°C

Operating Temperature
(Electrical connection “F”, DIN 43650-A)
-20 to +80°C

Media Temperature
-40 to +125°C

Media Temperature
(Electrical connection “F”, DIN 43650-A)
-40 to +105°C

Compensated Temperature
0 to +55°C

Storage Temperature
-40 to +125°C

TC Zero
≤ ± 1% of FS
≤ ± 2% of FS (2 PSI & below)

TC Span
≤ ± 1% of FS
≤ ± 2% of FS (2 PSI & below)

Environmental

EMI/RFI Protection
Yes

IP Rating*
IP65 minimum

Vibration
10g, 20 to 5000Hz

Shock
100g, 11msec, 1/2 sine

* IP Rating is dependent on electrical termination selected. Contact factory for more information.
* IP Rating applies when electrical connector is attached with the appropriate ingress protection.

Electrical (Current)

Outputs
4-20mA

Excitation
10-28VDC

Current Consumption
20mA, typical

Output Load
0-800 Ohms @ 10-28VDC

Frequency Response (min)
~250Hz

Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max

Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Electrical (Voltage)

Outputs
1-5V

Excitation
10-28VDC

Current Consumption
<10mA

Output Load
5K Ohms, min

Frequency Response (min)
~1kHz

Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max

Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Electrical (Ratiometric)

Outputs
0.5-4.5V ratiometric

Excitation
5VDC +/- 0.5V

Current Consumption
<10mA

Output Load
5K Ohms, min

Frequency Response (min)
~1kHz

Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max

Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Electrical (Low Power)

Outputs
0.5-2.5V non-ratiometric

Excitation
3-5VDC unregulated

Current Consumption
≤ 3mA

Output Load
5K Ohms, min

Frequency Response (min)
~1kHz

Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max

Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max