Numens -Â Model 4001-02 -non-addressable control panel for house security
The 4001-02 non-addressable control and indicating equipment forms the central part of a fire detection and alarm system. The 4001-01 is compatible with Numens non-addressable devices. The 4001-02 comes standard with features that allows flexibility and expandability. Default configuration programming facilitates out-of-box installation and rapid commissioning. The 4001-02 control panel provides fire detection and alarm system designers with an economical product for life safety and property protection applications.· 4 detection zones
· Supports up to 32 non-addressable devices per alarm zone circuit
· Configurable non-latching alarm zones
· Configurable alarm dependency (zone coincidence detection)
· Configurable timer to delay output activation (up to 10 min)
· Capacitor end-of-line device.
· 3 Access Levels
· Single-person test mode
· Day/night mode configurable
· Manual activation of alarm devices
· Supervised auxiliary DC 24 V output
· 2 programmable non-addressable alarm output circuits
· 2 unmonitored relay contacts for Fire Alarm Condition outputs
· 1 unmonitored relay contact for Fault Condition output
· 3 voltage-free inputs for remote reset, evacuation start/stop, and Day/Night mode
· Clear alarm zone LED indicators, with a single indicator for Fault, Disable and Test Condition indication
· Recessed mounting enclosure
· Supports up to 7 Repeater Panels
· Easy installation
|
|
4001-02 |
|
Operating voltage |
AC (85 ~ 260) V / 50/60 Hz |
|
Mains supply current limit |
720 mA @ AC 230 V |
|
Mains supply fuse |
4 A / AC 250 V slow blow (20 mm) |
|
Mains supply fault threshold voltage |
≤ AC 60 V |
|
Power supply |
2.2 A @ DC 28.5 V |
|
Standby battery maximum capacity (2 × DC 12 V) |
7.2 Ah |
|
Maximum battery current draw |
1.5 A @ maximum operating temperature |
|
Battery fuse |
6 A resettable (electronic fuse) |
|
Battery fault threshold voltage |
< DC 20 V |
|
Quiescent current |
30 m A @ DC 28 V |
|
Detection zone circuits |
4 |
|
Number of connected devices per detection zone circuit |
32 |
|
Detector zone quiescent current |
5 mA |
|
Detector zone alarm current |
80 mA |
|
Detector zone wiring characteristics (max) |
40 ? / 0.47 µF |
|
Detection zone end-of-line capacitor |
22 µF / DC 50 V |
|
Manual call point resistor value |
(470 ~ 689) ? |
|
Alarm zone outputs |
2 |
|
Alarm zone current |
910 mA |
|
Alarm zone end-of-line resistor |
(20 ~ 40) k? |
|
Alarm zone monitoring |
Open- and short-circuit |
|
Alarm zone voltage (max) |
DC 27.5 V |
|
Alarm zone fuse |
1.1 A resettable (electronic fuse) |
|
Number of programmable output relays |
2 |
|
Ancillary fire C/O relay |
2 × (1.0 A @ DC 30 V / 1 A @ AC 240 V) |
|
Ancillary fault N/C relay |
1.0 A @ DC 30 V / 1 A @ AC 240 V |
|
Auxiliary supply |
DC 28 V @ 300 mA |
|
Evacuation start / stop |
Non-latching, voltage-free |
|
Day / Night mode |
Non-latching, voltage-free |
|
Remote reset |
Non-latching, voltage-free |
|
Terminal wiring |
(0.4 ~ 2.5) mm2 |
|
Operating temperature |
(0 ~ +50) °C |
|
Operating humidity |
(0 ~ 95) % RH, non-condensing |
|
Storage temperature |
(-25 ~ +80) °C |
|
Storage humidity |
(0 ~ 98) % RH, non-condensing |
|
Dimensions (h × w × d) |
(402 × 337 × 99) mm |
|
Weight (excluding batteries) |
4.0 kg |
|
|
EN 54-2 a |
EN 54-4 b |
|
4001-01 |
√ |
√ |
|
4001-02 |
√ |
√ |
|
4001-03 |
√ |
√ |
|
4001-04 |
√ |
√ |
|
aEN 54-2 Control and indicating equipment b EN 54-4 Power supply equipment |
||