The 4001-03 non-addressable control and indicating equipment forms the central part of a fire detection and alarm system. The 4001-01 is compatible with Numens non-addressable devices. The 4001-03 comes standard with features that allows flexibility and expandability. Default configuration programming facilitates out-of-box installation and rapid commissioning. The 4001-03 control panel provides fire detection and alarm system designers with an economical product for life safety and property protection applications.

·          8 detection zones

·          Supports up to 32 non-addressable devices per alarm zone circuit

·          Configurable non-latching alarm zones

·          Configurable alarm dependency (zone coincidence detection)

·          Configurable timer to delay output activation (up to 10 min)

·          Capacitor end-of-line device.

·          3 Access Levels

·          Single-person test mode

·          Day/night mode configurable

·          Manual activation of alarm devices

·          Supervised auxiliary DC 24 V output

·          2 programmable non-addressable alarm output circuits

·          2 unmonitored relay contacts for Fire Alarm Condition outputs

·          1 unmonitored relay contact for Fault Condition output

·          3 voltage-free inputs for remote reset, evacuation start/stop, and Day/Night mode

·          Clear alarm zone LED indicators, with a single indicator for Fault, Disable and Test Condition indication

·          Recessed mounting enclosure

·          Supports up to 7 Repeater Panels

·          Easy installation

 

4001-01

Operating voltage

AC (85 ~ 260) V / 50/60 Hz

Mains supply current limit

720 mA @ AC 230 V

Mains supply fuse

4 A / AC 250 V slow blow (20 mm)

Mains supply fault threshold voltage

 AC 60 V

Power supply

2.2 A @ DC 28.5 V

Standby battery maximum capacity (2 × DC 12 V)

7.2 Ah

Maximum battery current draw

1.5 A @ maximum operating temperature

Battery fuse

6 A resettable (electronic fuse)

Battery fault threshold voltage

< DC 20 V

Quiescent current

30 m A @ DC 28 V

Detection zone circuits

8

Number of connected devices per detection zone circuit

32

Detector zone quiescent current

5 mA

Detector zone alarm current

160 mA

Detector zone wiring characteristics (max)

40 ? / 0.47 µF

Detection zone end-of-line capacitor

22 µF / DC 50 V

Manual call point resistor value

(470 ~ 689) ?

Alarm zone outputs

2

Alarm zone current

910 mA

Alarm zone end-of-line resistor

(20 ~ 40) k?

Alarm zone monitoring

Open- and short-circuit

Alarm zone voltage (max)

DC 27.5 V

Alarm zone fuse

1.1 A resettable (electronic fuse)

Number of programmable output relays

2

Ancillary fire C/O relay

2 × (1.0 A @ DC 30 V / 1 A @ AC 240 V)

Ancillary fault N/C relay

1.0 A @ DC 30 V / 1 A @ AC 240 V

Auxiliary supply

DC 28 V @ 300 mA

Evacuation start / stop

Non-latching, voltage-free

Day / Night mode

Non-latching, voltage-free

Remote reset

Non-latching, voltage-free

Terminal wiring

(0.4 ~ 2.5) mm2

Operating temperature

(0 ~ +50) °C

Operating humidity

(0 ~ 95) % RH, non-condensing

Storage temperature

(-25 ~ +80) °C

Storage humidity

(0 ~ 98) % RH, non-condensing

Dimensions (h × w × d)

(402 × 337 × 99) mm

Weight (excluding batteries)

4.0 kg

 

EN 54-2 a

EN 54-4 b

4001-01

                 √

4001-02

                  √

4001-03

                  √

4001-04

aEN 54-2 Control and indicating equipment

b EN 54-4 Power supply equipment