- Home
- Companies
- Enotec GmbH
- Products
- Enotec - Model 2000 - O2 & COe Analyzer
Enotec - Model 2000 -O2 & COe Analyzer
The explosion-proof COMTEC 6000 GasEx analysis system reacts immediately to changes in flue gas composition and is ideal for safe and accurate measurements of oxygen and CO2 in refineries or similar areas with a risk of explosion (Gas Ex Zones 1/2).
The explosion-proof COMTEC 6000 GasEx analysis system reacts immediately to changes in flue gas composition and is ideal for safe and accurate measurements of oxygen and CO2 in refineries or similar areas with a risk of explosion (Gas Ex Zones 1/2).
The ATEX certifications (II 2G Ex db IIC T3 Gb), successfully completed by a German testing institute, apply to all analyzer components, including those directly exposed to the flue gas. This certification creates confidence in plant safety and is coupled with the convincing quality of ENOTEC products, which consistently withstand the challenges of aggressive process conditions.
Developed for potentially explosive atmospheres
-
EX Marking: II 2G Ex db IIC T3 Gb
- Process gas temperature: max. 500 °C - max. 1400 °C with cooling protection tube
- Measuring principle O2: Zirconium oxide|MXP
- Immersion depth/material: 403 mm to 863 mm (others on request) / Stainless steel (SS316TI)
- Measuring principle COe: MXP (mixed potential)
- Ambient temperature: Probe: -40°C to +70°C | Electronics: -20°C to +55°C
- O2 - Measuring ranges: Two freely selectable measuring ranges: 0-2 Vol.% to 0-21 Vol.% (others on request)
- COe - Measuring ranges: 0 to 5000 ppm
- Housing: Probe: IP66 | Electronics: IP66
- Type of protection: II 2G Ex db IIC T3 Gb