OxyGuards developed ozone sensor is designed specifically for use in aquaculture. The sensor uses an entirely new innovative technology, and the partial pressure of ozone is measured directly without the use of electrolyte, reagents, light, or other traditional methods. As a result, there is almost no maintenance, the probe is exceptionally stable, and the response time is extremely fast. It can be used to control the ozone dosage of the Gaia Ozone Generator together with the Gaia control unit. With the possibility to measure ozone content in the water down to only a few μg/L, it is possible to ensure safe conditions for the stock!

Most popular related searches
  • Units of measure: PPM (mg/l).
  • Measuring ranges: Low: 0-0.8 mg/l (best between 0 and 0.5). High: 0.5-8 mg/l.
  • Operating temperature: 0-40 degrees Celsius (°C). 32-104 degrees Fahrenheit (°F).
  • Dimensions:
  • D: 40 mm, L: 104 mm.
  • D: 1.57 in., L: 4.09 in.
  • Cable length: Standard: 7 meters; any length available upon request.
  • Response time:
  • 90% in less than 45 seconds (for the low range type).
  • 90% (period yet to be specified for the high range type).
  • Medium: Water. Can be made for use in air upon request.
  • Installation:
  • The OxyGuard Ozone Sensor is designed to be connected to an OxyGuard Pacific system or an OxyGuard Marlin system.
  • Ordering information:
  • G20L: Ozone probe, for Pacific/Marlin, low measuring range 0-0.8 mg/l.
  • G20H: Ozone Probe for Pacific/Marlin, high measuring range 0.5-8 mg/l.