Oxymat A/S

OxymatNitrogen Generator Systems

SHARE

At Oxymat, we use two columns with molecular sieves to ensure continuous production. Dry compressed air is blown through a valve to the vessel where the pressure is built to reach 5 to 7 bar(g). Oxygen is tied to a molecular sieve during the building of pressure, and the nitrogen is allowed to pass through to the accumulation tank. While pressure is build in one vessel, the second remains without pressure. A part of the produced gas is used for regeneration of the molecular sieve. For Nitrogen a Carbon Molecular Sieve (CMS) is used. The molecular sieve is fully regenerative and has a life span on to 40.000 operation hours.

Most popular related searches

The entire PSA system can be subdivided into the following:

  • Compressed air system (Air compressor, Refrigeration dryer, Air receiver & Filters).
  • PSA skid
  • Nitrogen receiver
  • Nitrogen boosting & Filling Station (optional)

Optional supplies

  • Panel Display with electro galvanized sensor
  • Touch Screen with zirconium sensor
  • GSM modem for touch Screen
  • Medical upgrade kit (Coalescing tower and bacterial filtration)