PID AnalyzersModel 312 GC -Portable Gas Chromatograph System

SHARE

PID Analyzers offers a new lightweight portable GC for environmental, quality control, natural gas... applications. The base Model 312 comes with syringe injection, oven, power supplies & Pentium PC with Windows XP (embedded) and PeakWorks chromatography software in a rugged plastic case.

Most popular related searches
  • PID Lamps: Our 9.5 and 10.6 eV lamps remain the best in the business since we developed them over 30 years ago.
  • Display: Our 7`` Color VGA display (640 x 480 resolution) is easy to read. The display is a touch screen.
  • ADC: Our 16 bit ADCs provide a resolution of 1 part in 64,000 and our signal algorithm minimizes noise by signal averaging in the msec range; the ADC can acquire positive or negative signals.
  • Digital outputs: USB connection.
  • Oven:
    • Size:
      • Typical column diameter: 3.5``
    • Temperature range:
      • Battery: 25-50 Degrees Celcius
      • External power: 25-100 Degrees Celcius
  • FID: Our very sensitive FID has flame out sensor that will shut off the hydrogen if the flame goes out.
  • PC: Embedded Pentium Computer with > 1 GByte of RAM; data storage on 1 Gbyte USB memory stick.
  • Autoranging: The 312 has 3 ranges with computer controlled autoranging- x1, x 10, x 100.
  • Battery life: 3-4 hours; can operate off cigarette lighter adapter.
  • FPD: Our very sensitive FPD has flame out sensor that will shut off the hydrogen if the flame goes out.
  • Operating system: Windows XP® embedded stored on 2.5 GByte smart card (the PeakWorks program and all data are on the memory stick.
  • Autozero: Beginning of each run.
  • Carrier gas: 50 liters at 1500 PSI; typical capillary column 15-20 cc/min; typical packed column 30-40 cc/min.
  • Ease of calibration: Manual.
  • Peak Detection & System Operation: Controlled by our 32 bit PeakWorks software program with more than 20 years of development.
  • Programmable Voltage/current output: 0-1VDC.
  • Programmable setpoints: The low and high setpoints (depends on the options) can be customer programmed for each point and/or compound.
  • Detectors: Photoionization detector (PID), Flame ionization detector (FID), Thermal conductivity detector (TCD), Flame photometric detector (FPD), Far UV absorbance (FUV) detector, Catalytic combustion detector (CCD)
  • Linear Dynamic Range: PID - 108 FID - 2 x 106 TCD - 2 x 104 FPD- S - 103; P 105 Far UV - 106 CCD - 5 x 104
  • Sample Flow Rate: > 0.5 LPM
  • Power consumption: < 50 watts maximum; 115 VAC, 0.5 amps (12 VDC 5 amps)
  • Species measured:
    • PID & FID: Organics (VOCs by PID or FID) and inorganic species (H2S, NH3, AsH3… ) that can be ionized by the PID lamp (9.5, 10.6 or 11.7 eV)    
    • TCD: Universal detector- fixed gases (O2, N2, CO…), organic and inorganic compounds, very sensitive for H2, He, Xe    
    • FPD: Selective response for S or P compounds    
    • Far UV: Nearly universal response for organic and inorganic compounds    
    • CCD: Combustible compounds such as hydrocarbons    
    • Sensor(s): 1 or 2 detectors
    • Precision: +/- 1-2% of reading
    • Injection: On-column syringe injection or automatic with 6 port gas valve (optional)
    • Span Drift: <1% over 24 hours
    • Dimensions: Enclosure - 18.75``x 13.75`` x 7.5``
    • Weight: Fiberglass case - 27.5 pounds
  • Detection Limit:
    • PID - 0.5 ppb benzene
    • FID - 50 ppb benzene
    • TCD - H2- 10 ppm; O2 150 ppm
  • Response time: Depends on retention times
  • Zero Drift: NA- autozero on each run
  • Instrument operating conditions: 5-40 degrees C, 0-95% RH (non-condensing)