- Home
- Companies
- MRU Messgerate fur Rauchgase und ...
- Products
- MRU - Model NOVAplus MCERTS - Portable ...
MRU - Model NOVAplus MCERTS -Portable Flue Gas Analyzer
The combination of infrared measurement technology and electrochemical sensors ensures versatility and reliable analysis even of small measuring ranges.
Most popular related searches
gas flow monitoring
peltier gas cooler
portable flue gas analyzer
sample gas
gas cooler
flow monitoring
mass flow monitoring
gas sampling probe
emissions monitoring system
portable flue gas
See TÜV Rheinland certificate
- Complying with MCERTS performance standards for transportable emission monitoring systems
- Maximum flexibility through wireless remote control
NOVAplus MCERTS base unit:
- Robust metal enclosure mounted to an aluminium framed case
- Docking station for remote control with inductive charging function of RCU
- Built-in speedprinter
- Auto-zero solenoid valve for long-term measurementsand internal sample gas flow monitoring and alarm
- Peltier gas cooler with automatic condensate draining pump, with condensate monitoring and alarm
- Emission calculations like: : mg/m3, NOx as mg/m3 NO2, true measurement of NOx = NO + NO2, including O2 referencing (normalisation) to user settable value
- High energy lithium-ion battery and universal grid power supply 100-240Vac / 50-60 Hz, 12 Vdc, 60
- Industrial gas sampling probe using heated, easy replaceable quartz glass wool filter, with 2700 mm unheated Viton sample line and gas temperature measurement with K-type thermocouple (without exchangeable probe tubes)
NOVAplus MCERTS included remote control unit "Comfort":
- Wireless remote control of all instrument functions
- Backlit 3,5“TFT colour display
- Automatic measurement with data storage of measured values on SD card
- SD card (2 GB), mini USB port, internal memory for 16.000 data sets
- Contactless battery charging
- Lithium-ion battery with inductional charging, for approx. 30 hours mains free operation
- Differential pressure 0 ... +/- 100 mbar
- Gas flow velocity and mass flow measurement by using of Pitot tube (option)
Measuring range
- O2: 0 ... 25 % (electrochemical, long-life)
- CO (H2 compensated): 0 ... 4.000 ppm* overload up to 10.000 ppm (electrochemical)
- CO low: 0...300ppm
- NO: 0...1.000 ppm
- NO low: 0...300ppm
- NO2: 0 ... 200 ppm* overload up to 1.000 ppm (electrochemical)
- NO2 low: 0...300ppm (0,1ppm resolution)
- NO(x): 0 ... 1.000 ppm* overload up to 5.000 ppm (electrochemical)
- SO2: (option) 0 ... 2.000 ppm* overload up to 5.000 ppm (electrochemical)
- SO2 low: 0...300ppm (0,1ppm resolution)
- H2S: 0...500pm, Überlast < 2.000 ppm
- H2S low: 0...300ppm (0,1ppm resolution)
- CO2: (option) 0 ... 20,00%* overload up to 40,00% (infrared)
- Differential pressure: at basic unit ± 100hPa, at remote control ± 200hPa
- External pressure sensor: up to 40 bar (option)
- Fluegas temperature: up to 1.100 °C (K-type thermocouple)
- Amount of leakage: 0 ... 8 l/h
- External temperature sensor: K-type standard
- Relative humidity: 3...98%
Calculated values
- Dew point: calculated °C
- Losses: 0 ...99,9 %
Dimensions and other data
- Gas conditioning: Peltier gas cooler with automatic condensate draining pump, with condensate monitoring and alarm
- Sample gas flow monitoring: internal sample gas flow monitoring and alarm
- Operating temperature: + 5 ... + 45 °C, max. 95 % RF, non condensing
- Power supply: grid 100 ... 240 Vac / 50 … 60 Hz, 1,4 A, 12 V DC/5A
- Battery capacity: basic unit with gas cooler 10 hours / remote control 30 hours
- Weight: 7,4 kg with 2 sensors, probe, power supply, case
- Dimensions: 470x314x235 mm (HxWxD)
- TÜV approval: By RgG 296
- Data storage: internally 1MB and externally on SD card 2 GB
- Data transfer: via USB-cable, optionally via Bluetooth
- PC-interface: mini-USB, optionally Bluetooth
- Display: 3,5" TFT colour display