Servoflex - Model Micro i.s. 5100 -Portable Gas Analyzer
High performance oxygen, carbon monoxide and carbon dioxide portable gas analysis, designed for use in hazard rated locations including Zone 0/Division 1.
Most popular related searches
portable gas
gas analysis
hazardous area combustion
portable gas analyzer
hazardous area regulations
carbon dioxide pump
sensor system
hazardous area
toxicity sampling
gas analyzer
- Designed to meet the demands of the most dangerous environments, Micro i.s. delivers ultra-sensitive percentage measurements for oxygen, carbon monoxide and carbon dioxide. A tough, life-proof design and feature-rich performance ensures maximum operational flexibility.
- Micro i.s. is Intrinsically safe (i.s.) and is able to analyze both flammable and toxic samples. This intelligent design means that no purge is required prior to device use.
- Micro i.s. also provides an intuitive user interface, the ability to store up to 200 measurements and up to 18 hours battery run time.
Flexible
- Intrinsically Safe (i.s.) design permits use in any hazard rated location including Zone 0/Divisional 1
- Gas analysis for 02, CO or CO2
- Pumped or non-pumped (AFCD) FUNCTIONS
- IP65 rating
Easy to use
- Intuitive, engineer-friendly interface and icons
- Stores up to 200 measurements for subsequent download
- Ergonomic design with carry strap
Low cost of ownership
- Uses non-depleting sensor technologies that reduce ongoing maintenance costs
- Advanced Li-Ion rechargeable batteries as standard (up to 18 hour run time)
Unrivalled Performance
- Uses industry-leading patented Paramagnetic and IR technologies and algorithms for ultra-sensitive and accurate measurements
- Manufactured by Servomex - over 60 years’ experience innovating and pioneering gas analysis with thousands of units used in the field every year
Benchmark compliance
- ATEX: Ex ia (Intrinsically Safe) IIC T4 Ga (-10°C=Ta=+50°C) (+14°F=Ta=+122°F)
- IEC: Ex ia (Intrinsically Safe) IIC T4 Ga (-10°C=Ta=+50°C) (+14°F<_Ta=+122°F)
- FM: IS/I/1/ABCD/T4; -10°C=Ta=+50°C: IP65 (Division 1)
- FM: IS/I/0/AEx ia/IIC/T4; -10°C=Ta=50°C: IP65 (Zone 0)
- CSA: IS/I/1/ABCD/T4; -10°C=Ta=+50°C: IP65 (Division 1)
- CSA: IS/I/0/Ex ia/IIC/T4; -10°C=Ta=+50°C: IP65 (Zone 0)
Size
- 160mm (6.3”) Width x 185mm (7.2”) High x 140mm (7.2”) Deep
Weight
- 1.8kg – 2.3kg (4lbs – 5.1lbs)
Certifications
- ATEX: Ex ia (Intrinsically Safe) IIC T4 Ga (-10°C_<Ta_<+50°C) (+14°F_<Ta_<+122°F)
- IEC: Ex ia (Intrinsically Safe) IIC T4 Ga (-10°C_<Ta_<+50°C) (+14°F_<Ta_<+122°F)
- FM: IS/I/1/ABCD/T4; -10°C_<Ta_<+50°C: IP65 (Division 1)
- FM: IS/I/0/AEx ia/IIC/T4; -10°C_<Ta_<+50°C: IP65 (Zone 0)
- CSA: IS/I/1/ABCD/T4; -10°C_<Ta_<+50°C: IP65 (Division 1)
- CSA: IS/I/0/Ex ia/IIC/T4; -10°C_<Ta_<+50°C: IP65 (Zone 0)
- CE marked and in compliance with ATEX, EMC and WEE Directives scope UL approved and CE marked 100-240V / 43-70Hz AC power supply
- Hazardous area combustion optimization
- Natural gas processing
- Refineries – catalytic cracker regeneration
- HyCO applications
- Cracker decoke cycle on petrochemical plant
- Process monitoring
- Inerting applications
Ensure your SERVOFLEX Micro i.s. 5100 analyzer delivers optimum performance with Servomex Service Network.
Through our global network of engineers and service centers, we provide complete lifetime support for your analyzer. Our services range from installation and commissioning to supplying high quality spares and arranging scheduled servicing: visit our Service Network pages to find out more.