H2trOnics, Inc
  1. Companies
  2. H2trOnics, Inc
  3. Products
  4. Pyxis - Model SP-910 - Portable Water ...

PyxisModel SP-910 -Portable Water Analyzer

SHARE

The Pyxis SP-910 redefines the portable water analyzer by emphasizing all-in-one convenience and accuracy with a Fluorometer / Colorimeter / Turbidimeter.

Most popular related searches
  • PTSA and Fluorescein – Measure PTSA and Fluorescein in the same meter for your traced programs in cooling and boiler applications.
  • Calibrate ST-500 Directly – Calibrate a nearby ST-500 via built-in bluetooth after measuring sample concentration. No laptop or any other tool needed.
  • LIVE Graphical Value Display Reduces/Eliminates Wait Time for Plateau Results
  • Wireless Data Transfer to Cloud Data Management Capable
  • User Defined Programs – User defined programs supported with non-linear calibration curves. 60+ programs including reagent-less nitrite and chlorine dioxide measurement.
  • Battery Life Doubled – Six months or more under typical usage even equipped with higher resolution LCD readable in direct sunlight.
  • Product Name / Direct Read (ppm) Programmable
  • More Upgrades – Turbidity range extended to 0-100 and 0-1000 NTU with auto ranging. 16mm tube adaptor available for programs require digestion.

New Test Capability

  • PAA (10-500 ppm)
  • Direct Read Bleach Concentration (0-16%)
  • Direct Read ClO2 (7.3-50ppm)
  • MonoChlorAmine (0.1- 3.0 ppm)
  • Non-hazardous Zinc

All-In-One Convenience

The SP-910 features an intuitive graphical design with a minimal amount of keys. With the SP-910 designed as an all-in-one product, water treaters can reduce the number of devices needed for testing. The SP-910 works as:

A Fluorometer

  • 0-300 ppb (PTSA); 0-600 ppb (Fluorescein)

A Colorimeter

  • 420, 455, 525, 560, 570, and 610 nm
  • Compatible to Hach® methods

A Turbidimeter

  • 0-100 / 0-1000 NTU  Auto Range

And More

  • PAA (10-500 ppm)
  • Direct Read Bleach Concentration (0-16%)
  • Direct Read ClO2 (7.3-50ppm)
  • MonoChlorAmine (0.1- 3.0 ppm)
  • Non-hazardous Zinc
  • Range: 0-300 PPB PTSA; 0-600 ppb Fluorescein
  • Colorimeter Wavelength: 420, 455, 525, 560, 570, and 610nm
  • Turbidity Excitation Wavelength: White and IR LED
  • Fluorescence Excitation Wavelength: 365 / 470 nm LED
  • Fluorescence Emission Wavelength: 410 / 525 nm
  • Wavelength Accuracy: ±1 nm
  • Absorbance Reproducibility: 0.005 au in the range of 0 to 1.0 au (3 sigma)
  • Absorbance linearity range: 0 to 1.0 au
  • Turbidity Reproducibility: 2 NTU (3 sigma)
  • Fluorescence Detection Limit: 1 ppb PTSA / 0.1 ppb Fluorescein
  • Turbidity Detection Limit: 1 NTU
  • Display: LCD display, visible under direct sunlight
  • Temperature Range: 40 to 106 ℉ (4 to 41 ℃)
  • Environmental: IP67, dustproof and waterproof