H2trOnics, Inc
- Home
- Companies
- H2trOnics, Inc
- Products
- Pyxis - Model SP-910 - Portable Water ...
Pyxis - Model SP-910 -Portable Water Analyzer
FromH2trOnics, Inc
The Pyxis SP-910 redefines the portable water analyzer by emphasizing all-in-one convenience and accuracy with a Fluorometer / Colorimeter / Turbidimeter.
Most popular related searches
portable water analyzer
water analyzer
chlorine dioxide monitoring
portable analyzer
sample concentration
turbidity detection
chlorine dioxide
colorimetry
digestibility testing
digestibility test
- PTSA and Fluorescein – Measure PTSA and Fluorescein in the same meter for your traced programs in cooling and boiler applications.
- Calibrate ST-500 Directly – Calibrate a nearby ST-500 via built-in bluetooth after measuring sample concentration. No laptop or any other tool needed.
- LIVE Graphical Value Display Reduces/Eliminates Wait Time for Plateau Results
- Wireless Data Transfer to Cloud Data Management Capable
- User Defined Programs – User defined programs supported with non-linear calibration curves. 60+ programs including reagent-less nitrite and chlorine dioxide measurement.
- Battery Life Doubled – Six months or more under typical usage even equipped with higher resolution LCD readable in direct sunlight.
- Product Name / Direct Read (ppm) Programmable
- More Upgrades – Turbidity range extended to 0-100 and 0-1000 NTU with auto ranging. 16mm tube adaptor available for programs require digestion.
New Test Capability
- PAA (10-500 ppm)
- Direct Read Bleach Concentration (0-16%)
- Direct Read ClO2 (7.3-50ppm)
- MonoChlorAmine (0.1- 3.0 ppm)
- Non-hazardous Zinc
All-In-One Convenience
The SP-910 features an intuitive graphical design with a minimal amount of keys. With the SP-910 designed as an all-in-one product, water treaters can reduce the number of devices needed for testing. The SP-910 works as:
A Fluorometer
- 0-300 ppb (PTSA); 0-600 ppb (Fluorescein)
A Colorimeter
- 420, 455, 525, 560, 570, and 610 nm
- Compatible to Hach® methods
A Turbidimeter
- 0-100 / 0-1000 NTU Auto Range
And More
- PAA (10-500 ppm)
- Direct Read Bleach Concentration (0-16%)
- Direct Read ClO2 (7.3-50ppm)
- MonoChlorAmine (0.1- 3.0 ppm)
- Non-hazardous Zinc
- Range: 0-300 PPB PTSA; 0-600 ppb Fluorescein
- Colorimeter Wavelength: 420, 455, 525, 560, 570, and 610nm
- Turbidity Excitation Wavelength: White and IR LED
- Fluorescence Excitation Wavelength: 365 / 470 nm LED
- Fluorescence Emission Wavelength: 410 / 525 nm
- Wavelength Accuracy: ±1 nm
- Absorbance Reproducibility: 0.005 au in the range of 0 to 1.0 au (3 sigma)
- Absorbance linearity range: 0 to 1.0 au
- Turbidity Reproducibility: 2 NTU (3 sigma)
- Fluorescence Detection Limit: 1 ppb PTSA / 0.1 ppb Fluorescein
- Turbidity Detection Limit: 1 NTU
- Display: LCD display, visible under direct sunlight
- Temperature Range: 40 to 106 ℉ (4 to 41 ℃)
- Environmental: IP67, dustproof and waterproof