Pulsar Measurement
  1. Companies
  2. Pulsar Measurement
  3. Products
  4. Pulsar Measurement - Model MicroFlow - ...

Pulsar MeasurementModel MicroFlow -Non-contacting Microwave Liquid Velocity Sensor

SHARE

MicroFlow delivers accurate, repeatable velocity measurement of liquid flow, either as a stand-alone device or as part of a complete measurement system. MicroFlow builds on Pulsar`s award-winning pipe flow technology and world-leading open channel flow measurement systems.

Most popular related searches

MicroFlow can be installed as a stand-alone velocity sensor delivering data via RS485 Modbus or integrated within a complete system when combined with FlowCERT or Ultimate controller and dB series transducer.

Velocity x area calculation using MicroFlow provides a cost-effective flow measurement option compared to the installation of a primary measurement device such as a flume and provides a viable alternative where the hydraulics of the site do not allow for a restriction in the channel.

  • Non-contacting
  • Cost-effective
  • Lightweight, compact design
  • Minimal installation costs
  • No interruption to service
  • Maintenance-free
  • RS485 Modbus
  • IP68
  • Liquid Velocity Measurement
  • Open Channel Flow
  • Irrigation Channels
  • Rivers & Canals
  • PHYSICAL
    • Sensor body material: : Valox 357
    • Mounting connection: : Mounting bracket with 45º bend (optional)
    • Sensor body dimensions: : Diameter 86mm x Height 156mm (D 3.38in x H 6.14in)
    • Sensor weight: : Nominal 1kg (2.2lbs)
    • Transducer cable extensions: : Maximum 100m (328ft)
  • ENVIRONMENTAL:
    • Enclosure protection: : IP68
    • Max. and Min. temperature: : -20ºC to +70ºC (-4ºF to +158ºF)
    • Flammable atmosphere approval: : Safe area. (Hazardous area pending)
  • APPROVALS:
    • CE approval: : Complies with BS EN61326-1:2013 for emissions and immunity
    • RADAR approvals: : EN 300-440-1
    • EN 300-440-2
    • FCC 15.245
  • PERFORMANCE:
    • Operating voltage: : 10-28Vdc
    • Velocity range: : 0.2 - 6m/s
    • Accuracy: : The greater of ±0.5% or 0.03m/s
    • Optimum installation: : 45º optimum and mounted in the centre line of the channel with a clear uninterrupted view of the liquid surface
    • Level measurement: : Compatible with up to dB6 transducer
    • RADAR: : K Band (ISM)
    • Transmitter power: : <15dBm
    • Beam width: : 20º inclusive
  • OUTPUTS:
    • Communication: : RS485 and Modbus RTU - integrates with FlowCERT and Ultimate controller
  • PROGRAMMING:
    • PC Programming: : Via RS485 Modbus
    • Programming security: : Via passcode
    • Programming data integrity: : Via non-volatile memory
    • PC setup and monitoring software: : MicroFlow PC
  • SUPPLY:
    • Power consumption: : 0.5W maximum