Aethlabs
  1. Companies
  2. Aethlabs
  3. Products
  4. Aethlabs - Model microAeth AL80 - ...

AethlabsModel microAeth AL80 -Real-Time Black Carbon Aerosol Monitor

SHARE

The microAeth AL80 is a real-time Black Carbon aerosol monitor. This instrument comes in an outdoor rated enclosure with insulation, sampling inlet protection, and sun shield. It is lightweight and small enough to be quickly installed for measuring aerosol Black Carbon concentration in real-time without intervention for up to approximately 1-2 weeks. The microAeth incorporates the same Aethalometer measurement technology which has been used worldwide for over 40 years.

Most popular related searches

The AL80 is a self-contained instrument with a built-in, long life brushless pump, closed-loop flow control, and data storage. With new built-in WiFi technology, all data stored locally on the device can be downloaded directly over the device`s built-in WiFi interface or transmitted to AethLabs` cloud data management system in real-time or bulk data transfer when a network is available.

The instrument operates on wall or solar power continuously for up to approximately 1-2 weeks before the sampling filter must be exchanged. The air sample is collected on Polytetrafluoroethylene (PTFE) filter media. The filter media is housed in an easy to replace filter strip for simple handling in the field.

The microAeth AL80 is designed as a cost-effective outdoor instrument that can be used in fixed-site and mobile measurements.

  • Continuous real-time monitoring
  • Mobile monitoring
  • Daily filter life
  • Multi-week filter life
  • Exposure assessment
  • Health effects
  • Occupational safety
  • Ambient air monitoring
  • Stationary monitoring
  • Indoor air quality
  • Vehicle on-road mobile monitoring
  • Networks
  • Fence line monitoring
  • Near-road monitoring
  • Urban environment on street poles

  • Measurement Method: Real-time Aethalometer® method by measuring the rate of change in absorption of transmitted light due to continuous collection of aerosol deposit on filter. Measurement at 880 nm interpreted as concentration of Black Carbon (‘BC’).
  • Measurement Wavelength: 880 nm
  • Timebases (User setting): To be determined
  • Flow Rates (User setting): To be determined
Measurement Range
0-1 mg BC/m3, filter life time dependent on concentration and flow rate setting:
  • avg. 5 μg BC/m3 for 96 hours @ 100 ml/min
  • avg. 100 μg BC/m3 for 12 hours @ 50 ml/min
  • avg. 1 mg BC/m3 for 60 minutes @ 50 ml/min
  • Measurement Resolution" 0.001 μg BC/m3
  • Pump: Internal long life brushless diaphragm pump
  • Flow Control: Internal mass flowmeter with closed-loop control
  • Filter Material / Capacity: Polytetrafluoroethylene (PTFE) filter strip material with 1 sampling location per filter
  • Sampling: 6 mm spot created on filter strip containing insert of PTFE filter material. PM2.5 size selective inlet available.
  • Environmental Sensors: Temperature, Relative Humidity, Altimeter/Barometer, Accelerometer
Dimensions and Weight: 
  • Length: 266 mm (10.47 in) or 241.5mm (9.51 in) without inlet protection
  • Width: 262.4 mm (10.33 in)
  • Depth: 183 mm (7.21 in)
Without the sun shield, dimensions are:
  • Length: 202 mm (7.95 in) 
  • Width: 211 mm (8.31 in)
  • Depth: 166.8 mm (6.57 in)
  • Weight: 2325 grams (82 ounces) or 1389 grams (49 ounces) without back sun shield and inlet protection

Memory

  • 4 GB internal flash memory, providing data storage up to:
  • 9 years operating on 1 minute timebase
  • 55 days operating on 1 second timebase

Wireless Communications / Data Output

  • Data Stored in local memory.
  • Direct local data download over WiFi interface.
  • WiFi transmission to cloud data management system. Real-time and bulk data transfer when network is available 802.11 b/g/n Wi-Fi

Case: Outdoor Rated Sealed Enclosure with insulation and sun shield
Connections

  • M8 12V Power In (Power In Only)
  • USB-C 5V Power Out (Power Out Only)
  • 3.3V TTL Serial (Flow Calibration Communication)
  • Aerosol sample inlet and outlet ports
Power Supply Adapter

  • Input: 100~240 VAC 50/60 Hz 0.4 A
  • Output: 12VDC / 2A, M8 connector

Operation Environment: 5 ~ 40 °C operating, non-condensing.

Included

  • microAeth AL80 with sun shield
  • 1 filter strip (installed in instrument)
  • 1 territory-specific M8 AC wall adapter
  • 1 AL80 inlet protection kit
  • Manual available for download via AethLabs website

Physical Features

  • Sealed outdoor rated enclosure
  • Sun shield and internal insulation ro reduce effects of direct solar radiation
  • Integrated mounting bracket for easy pole or wall installation
  • Integrated mounting features for AL80 Inlet protection kit
  • Secure encrypted communication

Key Features

  • Setup, configuration, and management over local WiFi network
  • Remote device management via internet over WiFi
  • Data are accessible directly from local network WiFi Interface and remotely via AethLabs website & API
  • Store-and-forward data buffering to reduce impact of network outages