Herberts Industrieglas GmbH & Co. KG
Herberts - Model Type LSG-P -Rectangular Sight Glass Fittings
For viewing the internals of vessels, silos, reactors etc. mainly used as fluid level indicator
Most popular related searches
Operating conditions
- Pressure: 16 bar
- Vacuum
- It is strongly recommended to check the strength of reinforcement around the cutout in combinatation
with the vessel wall according to the regulations
AD Merkblätter TÜV data sheet B9
Certifications
- TÜV-pretested
Material certificates
- Test certificate EN10204-3.1B
- Alternative 3.1C (3.1A) is available at extra cost
Operating temperature
- 100°C soda lime glass DIN8903
- 243°C borosilicate glass, DIN7081
Those temperatures refer to unprotected glass plates, i.e without mica protective sheet