RMA Fiventures Asia-Pacific Pte Ltd.

RMAHigh Integrity Pressure Protection System (HIPPS)

SHARE

The HIPPS is provided for protection of downstream facilities from over pressure. If the pressure reading from 2oo3 pressure transmitters at HIPPS skid is above the set point, the HIPPS will activate the closure of two HIPPS valves in order to cut the gas supply to the downstream. The SIL-3 rated process safety system shall be provided for HIPPS.

Most popular related searches
  • Skid mounted
  • Pneumatic/Hydraulic operated actuator
  • Partial stroke test
  • 2oo3 configuration
  • 2×100% redundant fault-tolerant PLC control system
  • SIL 3 compliance
  • Design according to IEC 61508 and IEC 61511