Sabio - Model 6060 -TRS Analyzer
The Model 6060 UV TRS Analyzer provides accurate measurement of TRS (Total Reduced Sulfur) or TS (Total Sulfur) gas in air or low source levels from industrial processes. The Model 6060 TRS analyzer uses the same optical bench as the Model 6020 UV Sulfur Dioxide analyzer. An efficient external TRS oxidizer/converter thermally converts all sulfur gases to SO2. SO2 (Sulfur Dioxide) gas that may be present in the sample gas passes through the TRS converter unaffected. TRS and SO2 combined in the sample gas is called TS. If only TRS gas is the gas of interest, an SOX (SO2 Scrubber) is attached to the rear of the Model 6060 and plumbed in series to remove any SO2 gas that may be present. If there are other sulfur gases present in the sample gas, they will pass through the SOX scrubber and TRS converter unaffected and not measured. The 6060 Analyzer offers a bright color display, data logging capability and advanced communications via Ethernet, USB and RS-232/485.
- Ranges: 0-25 ppb to 0-2 ppm user set.
- Large color TFT LCD display
- Various user interface options including touch screen, front panel keypad, external keyboard and mouse
- Menu driven software
- Ethernet, USB and RS-232/485 ports
- Front panel USB connections for peripheral devices and firmware updates
- Four independent analog outputs with flexible ranges
- 8 digital input/outputs (I/Os)
- Automatic temperature and pressure compensation
- Comprehensive internal data logging
- Modbus protocol
- Rear mounted SOX Scrubber or H2S Scrubber
- Humidifier for SOX Scrubber to keep SOX scrubber material active in dry climates.
- Dilution module for measurement of low levels of TRS and H2S in CO2 gas for the beverage industry.
- EPA Approved Ranges: 0-25 ppb to 0-2 ppm user set
- Noise: < 0.0005 PPM
- Lower Detectable Limit: < 1 ppb
- Zero Drift: < ±.003 PPM per 24 hours
- Span Drift: < ±1% URL per 24 hours
- Cycle Time: 1 sample/second
- Precision Linearity: <1%ofURL
- Sample Flow Rate: 0.4 to 0.8 LPM
- Operating Temperature: 5° to 40° C (EPA Approved Range)
- Operating Humidity: 0 to 90%, non-condensing
- Power Requirements: 200 Watts, TRS Converter/ Oxidizer 500 Watts
- Voltage Output Ranges: 0.1V, 1V,2V,5V, 10V, user selectable
- Input/Output Ports: 0.1V,1V,5V,10V or other, user selectable with over & under range
- Physical Dimensions (H W x D) S02 Analyzer: x 5.25 in. x 17 in. x 22.5 in. (133 x432 x571.5 mm)
- Physical Dimensions (H W x D) TRS Converter: x 5.25 in. x 17 in. x 17 in. (133 x432 x432 mm)
- Weight: 25 lbs. (10.3 kg)
- Certification - S02 Bene: hUS EPA: RFSA-0616-237