Selerity - Model Series 4000 -Supercritical Fluid Chromatograph
The Selerity Series 4000 SFC was designed specifically for separations performed on microbore packed or capillary columns, in which a precision and pulse-free delivery of the mobile phase is critical. All systems are equipped with a flame ionization detector, optional specialty detectors, a low volume rotary injection valve, and a 10 mL high-pressure syringe pump. The Selerity Model 4000 SFC utilizes a Microsoft Windows 10 PC-based Agilent OpenLAB EZChrom chromatography data system software for signal acquisition and full instrument control.
Most popular related searches
high-pressure syringe pump
flame ionization detector
chromatography data system software
syringe pump
packed column
chromatography data system
high-pressure pump
capillary column
flame ionization
flame detection system
High pressure syringe pump
- Delivers the supercritical carbon dioxide by controlling the set pressure; therefore, a pulse-free pressure is delivered throughout the column to the detector, with no dampening needed.
- Only a small amount of the carbon dioxide mobile phase is used for each analysis, and system is helium-free, reducing the total cost per analysis.
- Long lifetime for syringe pump seals and check valves, in comparison to reciprocating pump technologies.
- 1mm ID Packed columns are optimized for SFC methods
- 50 μm capillary columns with a variety of phases are utilized
- Each column is tested under SFC conditions
- Timed Split direct injections to minimize dead volume
- Split/Splitless injection available for enhanced peak shape
- Up to 10X improvement in retention time reproducibility
- Improvement in operating pressure accuracy
Instrument Footprint:
- Weight: 40 kg (88 lbs)
- Dimensions (h x w x d): 76 x 42 x 57 cm (30 x 16.5 x 22 in)
- Packed: 1 mm ID X 5, 10, 25 and 50 cm
- Capillary: 50 μm ID X 10 m
- Volume: 10 mL
- Pressure range: 80 to 400 atm
- Pump type: Pulse-free syringe pump
- Pump-head cooling: Peltier cooling, -5°C to 18°C
- Temperature range: 5°C above ambient to 200°C
- Temperature programming: 40°C to 200°C in 0.1°C increments
- Heated zones: Three
- Detector gas control: Electronic pressure control
- Temperature range: 5°C above ambient to 200°C
- Dimensions (h x w x d): 5 x 3 x 2 cm (2 x 1 x 1 in)
Injection:
- Volume: 0.06 μL to 0.5 μL
- Style: rotary injection valve, air actuated
- Mode: Conventional split, timed-split, and split/splitless
- Port volume: 0.40 mm
- Style: rotary 6 port, air actuated
- Standard detector: Flame ionization detector (FID)
- Temperature: 400°C, increments of 1°C
- Dynamic range: > 106
- Min. detection amount: >5 pg carbon/sec
- Design: Grounded jet
- Flow rate compatibility: Capillary to 1 mm ID packed columns
- Power: 110 volts or 220 volts