ADVANTAGE - Model LPRA -Stainless Steel Load Sensor
The new Hardy HI LPRA low profile, rocker load point assembly is designed for use on high capacity vessels. Each ADVANTAGE line load point consists of a stainless steel, rocker type matched load sensor with true hermetic sealing, C2 Second Generation Electronic Calibration capabilities and a 1/4 NPT conduit adapter.
Each Load Point with galvanized or stainless steel mounting hardware provides adjustable anti-lift off protection and is specifically designed to eliminate the effects of unwanted forces to provide exceptional accuracy. Its unique self-checking support, which limits unwanted horizontal movement doubles as a dummy load cell for safe easy installation.
A grounding strap, fixed family color code wiring label, thirty feet of cable and installation manual are provided with each load point. The HI LPRA is available in the following capacities: 33 KLB and 50 KLB, and are available as individual load points or in tree or four leg systems.
The Hardy HI LPR Series Hermetic Load Point System is designed to provide accurate output in the most demanding applications. The load sensor performance exceeds IP68 and NEMA 6 Standards for Wash Down Resistance. The HI LPR Advantage, Low Profile, Rocker Load Point Systems are designed for use on high capacity vessels.
- Rated Output (F.S.): 2 ± 0.002 mV/V
- Non-Linearity: ± 0.012 %R.O.
- Hysteresis: < ±0.025 %R.O.
- Zero balance: < ± 1.0 % R.O.
- Creep @ 5 Min.: < ± 0.010 % R.O.
- Temp Effect Output: < ± 0.0014 % R.O/C.
- Temp Effect Sensitivity: < ± 0.0005 % R.O/C.
- Input Resistance: 1150 ± 50 ohm
- Output Resistance: 1000 ± 10 ohm
- Insulation Resistance: >5000 Mohm
- Excitation: 5 - 15 vdc
- Safe Load Limit: 200 % Emax
- Ultimate Load: 300 % Emax
- Safe Side Load: 100% Emax
- mv/V/ohm: 0.002 ± 0.1%