Reaction Distributing Inc.
  1. Companies
  2. Reaction Distributing Inc.
  3. Products
  4. Tri-Pak - Model T-20X Series - ...

Tri-PakModel T-20X Series -Stationary Compactor

SHARE

The T-20X stationary compactor has been specifically engineered to be used in multi-unit residential buildings and can be placed under a trash chute or used as a free standing system. It can be coupled with front-end containers or rear packer containers and will accept containers ranging in size from 1.5 to 4 cubic yards. The unit is available as a manually operated unit or when placed under a chute it can be supplied as a fully automated unit that will cycle unattended 24/7. It can also be used with our “tri-sorter and bi-sorter” head assemblies when the waste stream needs to be sorted.

Most popular related searches
  • UL/CSA Approved Design
  • Meets/exceeds ANSI Z245.2 regulations
  • Meets/exceeds OSHA regulations
  • PLC “flex-design” based control systems
  • NEMA 4 rated enclosure
  • Internal timers prevent system run-on
  • Self-diagnostic indicators
  • 24-volt controls
  • Adjustable multi-cycle timer
  • 75% and 100% full light
  • Auto-alert maintenance mode
  • Heavy duty oil-tight pushbutton controls
  • Key lockable start pushbutton

  • Advance-warning light
  • Fluid-filled pressure gauge
  • Oil heater
  • Odour control system
  • Open hopper (for top or dock loading)
  • Remote trouble/fill light
  • Sorter system
  • Charge Chamber Volume : 0.25
  • Charge Chamber Opening Size : 27″ x 25″
  • Ram Face Size : 27″ x 15″
  • Ram Penetration : 5″
  • Compaction Force Normal : 19,625 lbs
  • Compaction Force Maximum : 23,550 lbs
  • Cycle Time : 25 seconds
  • System Pressure Normal : 2000 psi
  • System Pressure Maximum : 2200 psi
  • Pump Capacity : 2 gpm
  • Motor Size : 1 hp
  • Cylinder Size : 2 x 2.5″
  • Cylinder Type : Double Acting
  • Ram Face Pressure Normal : 48.5 psi
  • Ram Face Pressure Maximum : 58.1 psi
  • Oil Tank Capacity : 5 gal
  • Shipping Weight : 950 lbs
  • Control System : 110 volt 60 cycle powered by step-down transformer
  • Control Panel : Fully wired. Keyed start button, emergency stop, full lights, reset button, PLC, current sensor
  • Power : 115 volt, single phase