CSA approved for use in hazardous locations, the intrinsically safe ultrasonic liquid level switch provides high or low liquid level detection of chemical, solvent or low viscosity petroleum based liquids with a 1A relay output. Media examples include hydrochloric acid, acetone and diesel fuel oil. The submersible PP or PFA level switch sensor is universally mounted through the tank wall or inside the tank, and connected to a PLC or relay controller.
Most popular related searches
liquid level switch
level switch
ultrasonic level switch
ultrasonic level
hydrochloric acid
hazardous area
corrosive liquid
water supply
PFAS
level sensor
- CSA approved intrinsically safe for use in hazardous environments
- Submersible PP or PFA Teflon® sensor and cable for corrosive liquids
- 60VA SPST relay selectable NO or NC via power supply wiring polarity
- Compatible with Smart Trak and Switch-Pak installation fittings
- Orientation: Universal
- Accuracy: ± 1mm in water
- Repeatibility: ± 0.5mm in water
- Supply voltage: 12-36 VDC
- Consumption: 25 mA maximum
- Contact type: (1) SPST relay
- Contact rating: GP: 60 VA, IS: 32 VDC @ 0.5A
- Contact output: Selectable NO / NC
- Process temp.: F: -40° to 176°, C: -40° to 80°
- Pressure: 150 psi (10 bar) @ 25º C, derated @ 1.667 psi (0.113 bar) per ºC above 25º C
- Sensor rating: -1XX5: NEMA 6 (IP68), -2XX5: NEMA 4X (IP65)
- Sensor material: -1XX5: PP, -2XX5: PFA
- Cable jack. mat.: -1XX5: PP, -2XX5: PFA
- Cable type: 4-conductor, shielded, #22 AWG
- Cable length: 10’ (3m)
- Process mount: 3/4” NPT (3/4”” G / Rp)
- Mount. gasket: Viton®
- Classification: Intrinsically safe
- Certificate: CSA, LR 79326
- Compliance: CE
- Approvals: Class I, Groups A, B, C & D; Class II, Groups E, F & G; Class III
- Parameters: Vmax = 32V, Imax = 300 mA, Pmax = 1.3W, Ci = 0 µF, Li = 0 µH