Tek-TrolModel TEK-BAR 3110B Series Smart -Differential Pressure Transmitter

SHARE

Tek-Bar 3110B Smart Differential Pressure Transmitter which uses the world’s most advance single crystal silicon pressure sensor technology and state of the art encapsulation technology. This is a high performance pressure transmitter with HART®communication protocol. It is used to measure liquid, gas or steam flow as well as liquid level, density, and pressure. It has good accuracy up to 0.075% of URL as well as IP66 water-proof protection.

Most popular related searches
  • Digital communication HART® protocol
  • High accuracy up to ±0.075%
  • It can be used to measure liquid, gas, and steam flow as well as liquid level, density, and pressure
  • Various Output: 4-20 mA, digital signals with HART®️ Communication (Modbus RS485)
  • Multiple temperature and linearity compensation to improve accuracy
  • Fully-sealed and fully isolated silicon pressure sensor
  • Superior stainless-steel process flange
  • Dual diaphragm overload protection, can easily cope with overload tests
  • Pressure Type 2 wire Smart Differential Pressure Transmitter
  • Reference accuracy ±0.075% F.S.
  • Wetted materials Hastelloy C and 316 L SS
  • Measuring Range 24″ W.C. to 1450 psid
  • Stability ±0.2% URL/5 year
  • Working temperature -40 °F to 185 °F (-40 °C to 85 °C)
  • Working humidity 5 to 100% RH at 104 °F
  • Output signal 4 mA to 20 mA with HART®️ Communication, Optional / Modbus RS485
  • Electrical connection ½” NPT Female
  • HART loop resistance 250 to 550Ω
  • Process connection ½”
  • Approvals CE, CSA Class I Div I
  • Weight (excluding option items) 8.81lb (without mounting bracket and process connection adapter)
  • Media temperature Silicon oil filling: -40 °F to 248 °F (-40 °C to 120 °C) Fluorocarbon oil filling: -49 °F to 320 °F (-45 °C to 160 °C)
  • Power Supply 10.5-55 VDC (Standard)
  • HART protocol 16.5-55 VDC, communication load resistance 250Ω
  • Load resistance 0-2119 for working condition, 250- 600Ω for HART Protocol
  • Transmission distance <1000 m
  • Power consumption ≤ 500 mW at 24 VDC, 20.8 mA